BO
Busy Out Settings
Function: Busy Out setting
Syntax:
stxBO:a,b,c,d;
(RS-232C, Command format: Type 2)
Syntax:
BO:a,b,c,d
(Telnet, Command format: Type 2)
a: Card in slot
0 Card in slot A
1 Card in slot B
2 Card in slot C
3 Card in slot D
b: During Delay Time
0
Off
1
On
c: During Phrase Play
0
Off
1
On
d: During Repeat Interval
0
Off
1
On
DO
Display Parameter Settings
Function: Display Parameter setting
Syntax:
stxDO:a,b,c,d;
(RS-232C, Command format: Type 2)
Syntax:
DO:a,b,c,d
(Telnet, Command format: Type 2)
a: Card in slot
0 Card in slot A
1 Card in slot B
2 Card in slot C
3 Card in slot D
b: Display Sleep
0
Off
1
On
c: Sleep Time (0M30S - 59M59S)
DC
Display Contrast Settings
Function: Display contrast setting
Syntax:
stxDC:a;
(RS-232C, Command format: Type 2)
Syntax:
DC:a
(Telnet, Command format: Type 2)
a: Display contrast (-10 - +10)
NT
Network data settings
Function: Network data settings
Syntax:
stxNT:a,b,c;
(RS-232C, Command format: Type 2)
Syntax:
NT:a,b,c
(Telnet, Command format: Type 2)
a: IP address setting
(0.0.0.0--255.255.255.255)
b: Net mask
(0.0.0.0--255.255.255.255)
c: Gateway
(0.0.0.0--255.255.255.255)
*
The above settings values become effective once the power has been turned off, then
on again.
AR-3000SD (Ver.1.00) Command Reference - 53