Power Supply NGMO
Unit Description
3-4
4.00 / 07-2004
3.3 Specifications
Channel 1
Channel 2
Constant-voltage source
- Voltage setting
0 to 15 V
0 to 15 V
- Resolution
1 mV
1 mV
- Deviation
0.05 % +5 mV
0.05 % +5 mV
• with
±
10 % AC supply variation
0.5 mV
0.5 mV
• from 10 to 90 % load change
0.01 % + 3 mV
0.01 % + 3 mV
- Transient recovery time on load
change (0.1 A to 1.6 A) to recover
within 20 mV
with wide bandwidth
• direct connected
<35 µs
<35 µs
• at “long” leads, sensed
<50 µs
<50 µs
with narrow bandwidth
• direct connected
<80 µs
<80 µs
• at “long” leads, sensed
<100 µs
<100 µs
- Transient voltage drop on load
change (0.1 A to 1.6 A)
with wide bandwidth
• at “long” leads, sensed
<60 mV
<60 mV
• ripple and noise
<1 mV
RMS
<1 mV
RMS
• output impedance
0 to 1
Ω
, settable in 10 m
Ω
steps
0 to 1
Ω
, settable in 10 m
Ω
steps
• voltage compensation
up to 1 V (4 V) per lead
up to 1 V (4 V) per lead
Constant-current source
- Peak current (1 ms)
7 A
7 A
- Current setting
• within 1.8 to 5 V
0 to 5 A
0 to 5 A
• outside 1.8 to 5 V
0 to 2.5 A
0 to 2.5 A
• resolution
1 mA
1 mA
Содержание NGMO1
Страница 8: ...Power Supply NGMO Tables 4 Version 4 00 07 2004 ...
Страница 14: ...Power Supply NGMO Safety 2 2 4 00 07 2004 ...
Страница 51: ...Operation Power Supply NGMO 4 00 07 2004 4 29 Fig 4 7 Status model structure ...
Страница 52: ...Power Supply NGMO Operation 4 30 4 00 07 2004 ...
Страница 56: ...Power Supply NGMO IEEE Commands 5 4 4 00 07 2004 Com mand Parameter Par value Description Def SCPI MAX DVMB ...
Страница 84: ...Power Supply NGMO Ordering Information 6 2 4 00 07 2004 ...