Technical Data
1
Technical Data
R&S®HMS-X
Spectrum analyzer with
frequency range up to 3
GHz
from firmware version 2.250
Frequency
Frequency range
basic unit
100 kHz to 1,6 GHz
with R&S®HMS-3G option /
with R&S®HV212 voucher
100 kHz to 3 GHz
Accuracy of the internal
reference
±2 x 10
-6
Temperature stability
±2 x 10
-6
(0°C to +30 °C)
Aging (per year)
±1 x 10
-6
Frequency counter
(with R&S®HMS-EMC option / R&S®HV213 voucher)
Resolution
1 Hz
Accuracy
±(frequency x tolerance of reference)
Span range
basic unit
0 Hz (Zero Span), 100 Hz to 1.6 GHz
with R&S®HMS-3G option /
with R&S®HV212 voucher
0 Hz (Zero Span), 100 Hz to 3 GHz
Spectral purity, SSB phase noise
(with
R&S®HMS-EMC option / R&S®HV213 voucher)
30 kHz from carrier
(500 MHz, +20°C to +30 °C)
<-85 dBc/Hz
100 kHz from carrier
(500 MHz, +20°C to +30 °C)
<-100 dBc/Hz
1 MHz from carrier
(500 MHz, +20°C to +30 °C)
<-120 dBc/Hz
Sweep time
f
span
= 0 Hz (zero span)
2 ms to 100 s
f
span
> 0 Hz
20 ms to 1000 s,
min. 20 ms per 600 MHz
Resolution bandwidths (-3 dB)
basic unit
10 kHz to 1 MHz (in 1 to 3 steps),
200 kHz
with R&S®HMS-EMC option /
with R&S®HV213 voucher
100 Hz to 1 MHz (in 1 to 3 steps),
200 kHz
Tolerance
f ≤ 300 kHz
±5 % typ.
f > 1 MHz
±10 % typ.
Resolution bandwidths (-6 dB)
with HMS-EMC (HV213) option CISPR: 200 Hz, 9 kHz, 120 kHz, 1 MHz
Video bandwidths
basic unit
1 kHz to 1 MHz (in 1 to 3 steps)
with R&S®HMS-EMC option /
with R&S®HV213 voucher
10 Hz to 1 MHz (in 1 to 3 steps)
Amplitude
Display range
Average noise level displayed up to
+20 dBm
Amplitude measurement range
basic unit
-104 dBm to +20 dBm (typ.)
with R&S®HMS-EMC option /
with R&S®HV213 voucher
n
-114 dBm to +20 dBm (typ.)
Max. voltage at HF input
80 V
DC
Technical Data
Max. power at HF input
20 dBm (permanently),
30 dBm (temporarily for max. 3 min)
Intermodulation-free range
TOI products, 2 x -20 dBm
(-10 dBm ref. level)
66 dB (typ.)
(typ. +13 dBm third-order-intercept)
signal distance ≤2 MHz
60 dB (typ., +10 dBm TOI)
signal distance >2 MHz
66 dB (typ., +13 dBm TOI)
DANL (displayed average noise level)
(ref. level ≤-30 dBm, frequency range 10 MHz to 3 GHz)
10 kHz (RBW), 1 kHz (VBW)
-95 dBm (typ. -104 dBm)
100 Hz (RBW), 10 Hz (VBW)
with R&S®HMS-EMC option /
with R&S®HV213 voucher
-115 dBm (typ. -135 dBm)
Preamplifier
with R&S®HMS-EMC option /
with R&S®HV213 voucher
-124 dBm (typ.)
Inherent spurious
ref.-level ≤-20 dBm,
f >30 MHz, RBW ≤100 kHz
<-80 dBm
Input related spurious (mixer level ≤-40 dBm)
Carrier offset:
1 MHz to 1.6 GHz
-70 dBc (typ.)
1.6 GHz to 3 GHz
with R&S®HMS-3G option /
with R&S®HV212 voucher
-55 dBc (typ.)
2nd harmonic receive frequency
Mixer level: -40 dBm
-60 dBc (typ.)
Level display
Reference level
-80 dBm to +20 dBm in 1 dB steps
Display range
basic unit
100 dB, 50 dB, 20 dB, 10 dB
with R&S®HMS-EMC option /
with R&S®HV213 voucher
linear
level display error
(ref. level -50 dBm, 20°C to 30 °C)
<1.5 dB (typ. 0.5 dB)
Display scaling
logarithmical
dBm, dBµV, dBmV
linear,
with R&S®HMS-EMC option /
with R&S®HV213 voucher
percentaged from reference level
Measured curves
1 curve and 1 memory curve
Trace mathematics
A-B (curve-stored curve), B-A
Detectors
basic unit
auto-, min/max. peak, sample, RMS,
average
with R&S®HMS-EMC option /
with R&S®HV213 voucher
same as basic unit, quasi-peak in
addition
Marker and delta marker
Number of markers
8
Marker functions
peak, next peak, minimum,
center to marker, frequency,
reference level to marker level,
all marker on peak
Marker display
basic unit
normal (level, logarithmic), delta
marker, noise marker, normal (linear)
with R&S®HMS-EMC option /
with R&S®HV213 voucher
(frequency) counter
Connectors
HF Input
Connector
N socket
Input impedance
50 Ω
VSWR (10 MHz to 3 GHz)
<1.5 (typ.)