List of Commands/Annex C
CTS30
1094.0006.30 C.24
E-4
1.5.3
Phase and Frequency Errors
1.5.3.1 Tolerances for Phase and Frequency Errors
Resetting to default values
Syntax:
CALCulate:LIMit:PHFR:CLEar
State:
ALL
Option:
none No Query
Note:
Sets the GSM,GSM850, DCS1800 or DCS1900 tolerances
Tolerances for phase and frequency error
Syntax:
CALCulate:LIMit:PHFR:TOLerance[:DATA] <numeric_value>, <numeric_value>, <numeric_value>
Value range:
0.0 ... 100.0 deg
(Peak phase error)
0.0 ... 25.0 deg
(RMS phase error)
GSM:
0 ... 200 Hz
(Frequency error)
GSM850: 0 ... 200 Hz
(Frequency error)
DCS1800: 0 ... 400 Hz
DCS1900: 0 ... 400 Hz
Default:
20.0
deg
5.0
deg
GSM: 90
Hz
GSM850: 90 Hz
DCS1800: 180 Hz
DCS1900: 180 Hz
State:
ALL
Option:
none With Query
Query for observance of tolerances
Syntax:
CALCulate:LIMit:PHFR:TOLerance:MATChing?
Return:
(MATC | NMAT | INV),
(Peak phase error)
(MATC | NMAT | INV),
(RMS phase error)
(MATC | NMAT | INV)
(Frequency error)
State:
MCE, RFG,
BAN
Option:
none Query only
Note:
Supplies the result for the last measurement, (N5), (N6)
Query for observance of the tolerances (average and maximum value measurement)
Syntax:
CALCulate:LIMit:PHFR:TOLerance:MATChing:AVERage?
CALCulate:LIMit:PHFR:TOLerance:MATChing:MAXimum?
Return:
(MATC | NMAT | INV),
(Peak phase error)
(MATC | NMAT | INV),
(RMS phase error)
(MATC | NMAT | INV)
(Frequency error)
State:
MCE, RFG,
BAN
Option:
none Query only
Note:
Supplies the result for the last measurement, (N5), (N6)