List of Commands/Annex C
CTS30
1094.0006.30 C.22
E-4
1.5.2.2 Power Measurement
Average power of the burst
Syntax:
Execute new
measurement and signal
result
Read result only
READ[:SCALar]:BURSt:POWer:AVERage?
FETCh[:SCALar]:BURSt:POWer:AVERage?
Return:
<value> (unit:
dBm)
State:
MCE, RFG,
BAN
Option:
none Query only
Note:
No default values, (N5)
Power values of the burst
Syntax:
Execute new
measurement and signal
result
Read result only
READ:ARRay:BURSt:POWer?
FETCh:ARRay:BURSt:POWer?
Return:
<value> {, <value>}
(unit: dB)
State:
MCE, RFG,
BAN
Option:
none Query only
Note:
No default values, (N5)
Peakvalue of the power
Syntax:
Execute new
measurement and signal
result
SENSe:POWer:PEAK?
Return:
<value> (unit:
dBm)
State:
MCE, RFG,
BAN
Option:
none Query only
Note:
No default values, (N5)
Power Measurement Mode Status
Syntax:
SENse:MODuletest:MEASurement:MODE?
Value range:
"SENSITIVE"
"NORMAL"
Default:
"NORMAL"
State:
MOD
Option:
Only query
Note
: