R&S FSH-K1
Command Description
1157.3564.12 61
E-8
LEVEL (Signal Level)
This command queries the signal level measured (fixed frequency/channel mode only).
Example:
get<cr>
0<cr>
level<cr>
‘query signal level
0<cr>
‘responds parameter ok
45.6<cr>
‘response:
signal
level
MEASTIME (Measurement Time)
This command defines the measurement time for the receiver mode.
Example:
set<cr>
0<cr>
meastime,5E-3<cr>
‘sets measurement time to 5 ms
0<cr>
‘responds parameter ok
SCANMODE (Scan Mode)
This command switches between frequency/channel scan mode and fixed frequency/channel mode.
Use the command CHMODE to toggle between frequency and channel mode.
Value
Scan Mode
0
Fixed Freq/Channel Mode
1
Feq/Channel Scan Mode
Example:
set<cr>
0<cr>
scanmode,1<cr>
‘selects
scan
mode
0<cr>
‘responds parameter ok
SCANSTART (Frequency Scan Start)
This command defines the scan start frequency for the frequency scan mode.
Example:
set<cr>
0<cr>
scanstart,88E6<cr>
‘sets scan start frequency to 88 MHz
0<cr>
‘responds parameter ok
SCANSTOP (Frequency Scan Stop)
This command defines the scan stop frequency for the frequency scan mode.
Example:
set<cr>
0<cr>
scanstop,108E6<cr>
‘sets scan stop frequency to 108 MHz
0<cr>
‘responds parameter ok