Command Description
R&S FSH-K1
1157.3564.12 56
E-8
TDMA Power
Command
Parameters
Unit
Comment
TDMAPWR
<numeric value>
GET command only
TDMASTD 0…1
MEASTIME <numeric
value>
s
LVLADJUST
CMD command only
TDMAPWR (TDMA Power)
This command queries the measured TDMA power.
Example:
get<cr>
0<cr>
tdmapwr<cr>
‘query power level from sensor
0<cr>
‘responds parameter ok
-32.45<cr>
‘response: TDMA power
TDMASTD (TDMA Power Standard)
This command defines the standard used for the TDMA power measurement.
Value
TDMA Power Standard
0
User
1
GSM / EDGE
Example:
set<cr>
0<cr>
tdmastd,1<cr>
‘select GSM/EDGE as standard
0<cr>
‘responds parameter ok
Note: If any customized standard was previously selected a value of ‘2’ will be returned as a response
to a GET TDMASTD query.
TDMACSTD (TDMA Customized Standard)
This command selects the customized standard for the TDMA power measurement previously loaded
with R&S FSHView software.
Example:
set<cr>
0<cr>
tdmacstd,MyStd<cr>
‘select MyStd as standard
0<cr>
‘responds parameter ok
Содержание 1157.3458.02
Страница 4: ......
Страница 5: ...R S FSH K1 Table of Contents 1157 3564 12 I 1 E 8...
Страница 6: ......