Operation
Operating Instructions for the TERZ 94 Electronic Turbine Meter
31
2. LF pulse scaler
TERZ 94
/
94-S
The frequency of the LF pulses is set by a pulse scaler (A07). There are the
following setting options: 0.01; 0.1; 1; 10; 100.
Other values can not be programmed, it is only possible to scroll in the list of
these values (‘t’ key vesp. ‘_’ key).
This pulse scaler has only effect on the frequency of the LF pulses not on the
display. The number of displayed digits after decimal point or a multiplier are
programmed as an operating mode (A08)
Recommended values (= values set in the factory)
DN
[mm]
Pulse
scaler
[pulses/m
3
]
LF decade
scaler
Pulse rate
[pulses/m
3
]
Maximum
output
frequency
[Hz]
1)
25 10
1
10
0.1
40 10
10
1
0.1
50 10
10
1
0.1
80 10
10
1
0.1
100
2)
10
10
1
0.1
150 1
1
1
0.3
200 1
1
1
0.6
250 1
1
1
0.7
300 1
1
1
1.1
400 1
10
0.1 0.2
500 1
10
0.1 0.3
600 1
10
0.1 0.4
1)
Rounded values
2)
In the case of the design with Q
max
=650
m
3
/h, the LF decade scaler is set at
1.
Содержание TERZ 94
Страница 2: ......
Страница 11: ...Safety Instructions Operating Instructions for the TERZ 94 Electronic Turbine Meter 9...
Страница 21: ...Installation Operating Instructions for the TERZ 94 Electronic Turbine Meter 19...
Страница 23: ...Installation Operating Instructions for the TERZ 94 Electronic Turbine Meter 21...
Страница 35: ...Operation Operating Instructions for the TERZ 94 Electronic Turbine Meter 33 3 Test protocol...
Страница 38: ...Operation 36 Operating Instructions for the TERZ 94 Electronic Turbine Meter All other values are not permitted...
Страница 62: ...Annex 60 Operating Instructions for the TERZ 94 Electronic Turbine Meter mode are blanked out...