Annex
Operating Instructions for the TERZ 94 Electronic Turbine Meter
53
Annex
Overview of Parameters for the TERZ 94/94-S
Parameter
Setting
Example
(display)
A01
Main totalizer (Vm)
0 to 99999999
12345678 m³
A02
Flow rate (Qm)
12.3 m³/h
A03
Disturbing quantity totalizer
0 to 99999999
123 m³
A04
Start-stop totalizer
0 to 99999999
12345678 m³
A05
Resettable totalizer
0 to 99999999
12345678 m³
A06
Meter factor
in all: six digits
12.3456 P/m³
A07
Pulse scaler
0.01; 0.1;1;10;100
L 1 --
A08
Configuration
TERZ operating mode
00011021 MOD
A09
Error
Rolling display
0 ERR
B01
Serial number
0 to 99999999
12345678 MOD
C01
Current output
12.345 mA
C02
Flow rate at 4 mA
0 to 999999.99
20.00 --
C03
Flow rate at 20 mA
0 to 999999.99
650.00 --
C04
Calibration current
4.000 to 20.000
4.000 mA
C05
Current output mode
0 – Default value
1 – Flow rate Qm
3 MOD
C06
Correction factor - Offset
0 to 99999999
1234.5678 --
C07
Correction factor - Rise
0 to 99999999
1234.5678 --
C08
Damping display / current
output
0 to 0.9
0.4 --
Z06
Frequency display
651 Hz
TERZ 94-S
Содержание TERZ 94
Страница 2: ......
Страница 11: ...Safety Instructions Operating Instructions for the TERZ 94 Electronic Turbine Meter 9...
Страница 21: ...Installation Operating Instructions for the TERZ 94 Electronic Turbine Meter 19...
Страница 23: ...Installation Operating Instructions for the TERZ 94 Electronic Turbine Meter 21...
Страница 35: ...Operation Operating Instructions for the TERZ 94 Electronic Turbine Meter 33 3 Test protocol...
Страница 38: ...Operation 36 Operating Instructions for the TERZ 94 Electronic Turbine Meter All other values are not permitted...
Страница 62: ...Annex 60 Operating Instructions for the TERZ 94 Electronic Turbine Meter mode are blanked out...