Specifications
Operating Instructions for the TERZ 94 Electronic Turbine Meter
41
Specifications
Measuring range
Under atmospheric pressure:
1:16
If the pressure increases, the measuring range of the meter extends.
Measuring ranges of up to 1:50 can be reached.
Measuring error
For Q
min
to
0.2
·
Q
max
:
≤
±2%
For 0.2
·
Q
max
to
Q
max
:
≤
±1%
(DN 25:
≤
±2% for Q
min
to Q
max
)
Reproducibility:
≤
±0.5%
Temperature ranges
Fluid temperature range:
-10°C
to
+50°C
Ambient temperature range:
TERZ 94
II2 G EEx ib IIC T4
-20°C to +40°C
II2 G EEx ib IIC T3
-20°C to +60°C
TERZ 94-S
II2 G EEx ib IIC T4
-20°C to +60°C
In the case of special designs, even higher or lower fluid temperatures are
possible in non-Ex versions.
Inputs and outputs
Sensor input S1
(Measuring input)
(For Ex connected loads, see approval certificate)
Terminals: X5,1
(+)
X5,2
(-)
Sensor type:
Wiegand sensor, direct
Line length < 50 cm
Jumpers X_S1 / 3-5 and 4-6
Wiegand sensor, remote totalizer
Line length < 30 m
Содержание TERZ 94
Страница 2: ......
Страница 11: ...Safety Instructions Operating Instructions for the TERZ 94 Electronic Turbine Meter 9...
Страница 21: ...Installation Operating Instructions for the TERZ 94 Electronic Turbine Meter 19...
Страница 23: ...Installation Operating Instructions for the TERZ 94 Electronic Turbine Meter 21...
Страница 35: ...Operation Operating Instructions for the TERZ 94 Electronic Turbine Meter 33 3 Test protocol...
Страница 38: ...Operation 36 Operating Instructions for the TERZ 94 Electronic Turbine Meter All other values are not permitted...
Страница 62: ...Annex 60 Operating Instructions for the TERZ 94 Electronic Turbine Meter mode are blanked out...