6 ERRORS
Manual ERZ2000-DI · EN1.2 · 2017, December 21st
110
36
W
09-5
H2>up.warn.lim.
Hydrogen exceeds upper warning limit
2
Yes
Yes
37
W
10-8
Def. channel 1
Channel 1 failed
1
No
No
38
W
10-9
Def. channel 2
Channel 2 failed
1
No
No
39
W
11-0
Start-up>max.
Meter start-up time too long
2
Yes
No
40
W
11-1
Slow-down>max.
Meter slow-down time too long
2
Yes
No
41
W
19-4
N2<l.warn.lim.
Nitrogen below lower warning limit
2
Yes
Yes
42
W
19-5
N2>up.warn.lim.
Nitrogen exceeds upper warning limit
2
Yes
Yes
43
H
30-0
Malloc error
Dynamic memory allocation error
1
No
No
44
H
31-9
CAN fault
CAN bus malfunction
2
No
No
45
A
32-1
BM failure
Failure of the billing-mode signal
2
Yes
Yes
46
M
33-0
Bill.Mod undef.
Undefined billing mode
1
No
No
47
M
33-1
Billing mode 1
Billing mode 1
1
No
No
48
M
33-2
Billing mode 2
Billing mode 2
1
No
No
49
M
33-5
DSfG-freeze
archive entry because attention f (freeze) on DSfG
1
No
No
50
H
40-1
old totalizer
Totalizer directly before setting of new value
1
No
No
51
H
40-2
new totalizer
Totalizer directly after setting of new value
1
No
No
52
R
40-7
Rebooted
Restart performed
1
No
No
53
H
42-1
RTC defective
Real time clock is defective
2
No
No
54
A
43-2
Def.tot.
Totalizer is defective
1
No
No
55
H
45-0
I1 inp.param.
Current input 1 parameterization error
2
No
No
56
H
45-1
I2 inp.param.
Current input 2 parameterization error
2
No
No
57
H
45-2
I3 inp.param.
Current input 3 parameterization error
2
No
No
58
H
45-8
PT1 inp.param.
Resistance input 1 parameterization error
2
No
No
59
H
46-0
Cont.param.error
Parameterization of contact input, double seizing
1
No
No
60
H
46-1
Vo defective
Vo transmitter shows unexpected behavior
2
No
No
61
H
46-2
Vo timeout
No more signal from Vo transmitter
2
No
No
62
H
46-3
Vo protocol
Vo protocol error
2
No
No
63
H
46-4
Deleted pulses
Stored pulses were deleted
1
No
No
64
H
46-5
I9 inp.param.
Current input 9 parameterization error
2
No
No
65
H
46-6
I10 inp.param.
Current input 10 parameterization error
2
No
No
66
W
47-0
Qm<l.warn.lim.
Flow rate at base conditions below lower warning limit
2
Yes
No
67
W
47-1
Qm>up.warn.lim.
Flow rate at measurement conditions exceeds
upper warning limit
2
Yes
No
68
W
47-2
Qmc<l.warn.lim.
Corrected flow rate at measurement conditions below
lower warning limit
2
Yes
No
69
W
47-3
Qmc>up.warn.lim.
Corrected flow rate at measurement conditions
exceeds upper warning limit
2
Yes
No
70
W
47-4
Qb<l.warn.lim.
Volumetric flow rate at base conditions below
lower warning limit
2
Yes
No
71
W
47-5
Qb>up.warn.lim.
Volumetric flow rate at base conditions exceeds upper
warning limit
2
Yes
No
72
W
47-6
Qe<l.warn.lim.
Energy flow rate below lower warning limit
2
Yes
No
73
W
47-7
Qe>up.warn.lim.
Energy flow rate exceeds upper warning limit
2
Yes
No
74
A
48-0
CAN timeout
CAN bus timeout
2
No
No
75
H
48-1
Def.modem
Modem is defective or switched off
1
No
No
Содержание ERZ2000-DI Series
Страница 6: ......
Страница 81: ...3 ELECTRICAL CONNECTIONS Manual ERZ2000 DI EN1 2 2017 December 21st 75 Figure 61 Rear wall of the ERZ2000 DI ...
Страница 99: ...4 TRANSMITTERS Manual ERZ2000 DI EN1 2 2017 December 21st 93 Figure 69 Measuring path arrangement USM GT400 ...
Страница 142: ...Certificates Manual ERZ2000 DI EN1 2 2017 December 21st 136 ...
Страница 143: ...Certificates Manual ERZ2000 DI EN1 2 2017 December 21st 137 ...
Страница 144: ...Certificates Manual ERZ2000 DI EN1 2 2017 December 21st 138 ...