6 ERRORS
Manual ERZ2000-DI · EN1.2 · 2017, December 21st
109
6.2
Error list
0
A
00-0
T loss
Loss of temperature
2
Yes
No
1
A
00-1
T<l.alarm lim.
Temperature below lower alarm limit
2
Yes
Yes
2
A
00-2
T>up.alarm lim.
Temperature exceeds upper alarm limit
2
Yes
Yes
3
W
00-4
T<l.warn.lim.
Temperature below lower warning limit
2
Yes
Yes
4
W
00-5
T>up.warn.lim.
Temperature exceeds upper warning limit
2
Yes
Yes
5
H
00-9
T param.error
Inconsistent parameterization, temperature
1
No
No
6
A
03-0
Pa loss
Loss of absolute pressure
2
Yes
No
7
A
03-1
Pa<l.alarm lim.
Absolute pressure below lower alarm limit
2
Yes
Yes
8
A
03-2
Pa>up.alarm lim.
Absolute pressure exceeds upper alarm limit
2
Yes
Yes
9
W
03-4
Pa<l.warn.lim.
Absolute pressure below lower warning limit
2
Yes
Yes
10
W
03-5
Pa>up.warn.lim.
Absolute pressure exceeds upper warning limit
2
Yes
Yes
11
H
03-9
Pa param.error
Inconsistent parameterization, absolute pressure
1
No
No
12
A
04-0
sd loss
Loss of standard density
2
Yes
No
13
A
04-1
sd<l.alarm lim.
Standard density below lower alarm limit
2
Yes
Yes
14
A
04-2
sd>up.alarm lim.
Standard density exceeds upper alarm limit
2
Yes
Yes
15
W
04-4
sd<l.warn.limit
Standard density below lower warning limit
2
Yes
Yes
16
W
04-5
sd>up.warn.lim.
Standard density exceeds upper warning limit
2
Yes
Yes
17
W
04-6
Vo warning
Vo failure, effect of fault: warning
2
Yes
No
18
H
04-7
HW pulse comp.
Hardware pulse comparison has taken effect
1
Yes
Yes
19
W
04-8
Run deviation
Quantitative comparison for synchronous run has taken effect
1
Yes
No
20
H
04-9
sd param.error
Inconsistent parameterization, standard density
1
No
No
21
W
05-7
Acc.puls.>max.
Too many temporarily stored pulses with open calibration lock
2
No
No
22
A
05-8
Vo alarm
Vo failure, effect of fault: alarm
2
Yes
No
23
A
06-0
Hs loss
Loss of superior calorific value
2
Yes
No
24
A
06-1
Hs<l.alarm lim.
Superior calorific value below lower alarm limit
2
Yes
Yes
25
A
06-2
Hs>up.alarm lim.
Superior calorific value exceeds upper alarm limit
2
Yes
Yes
26
W
06-4
Hs<l.warn.lim.
Superior calorific value below lower warning limit
2
Yes
Yes
27
W
06-5
Hs>up.warn.lim.
Superior calorific value exceeds upper warning limit
2
Yes
Yes
28
H
06-9
Hs param.error
Inconsistent parameterization, superior calorific value
1
No
No
29
A
07-0
CO2 loss
Loss of carbon dioxide
2
Yes
No
30
A
07-1
CO2<l.alarm lim.
Carbon dioxide below lower alarm limit
2
Yes
Yes
31
A
07-2
CO2>up.alarm lim.
Carbon dioxide exceeds upper alarm limit
2
Yes
Yes
32
W
07-4
CO2<l.warn.lim.
Carbon dioxide below lower warning limit
2
Yes
Yes
33
W
07-5
CO2>up.warn.lim.
Carbon dioxide exceeds upper warning limit
2
Yes
Yes
34
H
07-9
CO2 param.error
Inconsistent parameterization, carbon dioxide
1
No
No
35
W
09-4
H2<l.warn.lim.
Hydrogen below lower warning limit
2
Yes
Yes
Running
No.
Fault
category
Fault
number
Short text
Long text
Input enabled
No fault reported for Q=0
Valence
Содержание ERZ2000-DI Series
Страница 6: ......
Страница 81: ...3 ELECTRICAL CONNECTIONS Manual ERZ2000 DI EN1 2 2017 December 21st 75 Figure 61 Rear wall of the ERZ2000 DI ...
Страница 99: ...4 TRANSMITTERS Manual ERZ2000 DI EN1 2 2017 December 21st 93 Figure 69 Measuring path arrangement USM GT400 ...
Страница 142: ...Certificates Manual ERZ2000 DI EN1 2 2017 December 21st 136 ...
Страница 143: ...Certificates Manual ERZ2000 DI EN1 2 2017 December 21st 137 ...
Страница 144: ...Certificates Manual ERZ2000 DI EN1 2 2017 December 21st 138 ...