SteelCentral™ Enterprise NetProfiler Appliance Installation Guide

   

   15

        

Configuring the Expansion Modules

Configuring the Software

    Gateway:      10.38.128.1

NOTE: Setup will conclude with a reboot of this SteelCentral device.  After

all modules have rebooted, setup can be completed by logging into the UI at

    https://10.38.129.68/

Login as admin/admin.

NOTICE: All existing settings and logs will be lost.

Finish Setup and Reboot? (yes/no): 

yes

Working.....

5.

Wait until the system reboots before continuing to the next step.

6.

Using a system on the management network, log into the web user interface. Use the “admin” user name and 

password.
Enter the IP address that you specified for the User Interface Module in the configuration wizard. 

7.

The first time you log in, the initial Setup page is displayed. Enter the required information in all the fields marked 

with an asterisk (*). 

8.

Click 

Configure Now

 to complete the configuration.

9.

When prompted, enter a new password for the web user interface. 

You have successfully completed the installation of the basic modules of the Enterprise NetProfiler. 

Note: 

If the NetProfiler has Internet access, it attempts to download licenses from the Riverbed licensing server. You can add or 

download applicable licenses using the NetProfiler 

Configuration

Licenses

 page. Refer to 

Chapter 7, “Configuring License 

Keys.” 

If your system includes Expansion Modules and Dispatcher Modules, you can install them now by performing the 

same actions described for the other modules. 

Configuring the Expansion Modules

The Enterprise NetProfiler supports up to 19 Expansion Modules. If your system includes more than six (6) Expansion 

Modules, or if your flow rate is greater than 10M FPM, you must install a Dispatcher Module before you install the 

seventh Expansion Module. You do not need log into the web user interface to complete their configuration.

Important: 

You must use the same version of the software on all Enterprise NetProfiler modules. If you have Expansion Modules 

or a Dispatcher Module that is running a version different from the UI Module, refer to 

Chapter 8, “Adding Expansion Modules” 

for instructions on adding them to the system. 

On 

each

 Expansion Module

 you must complete the procedure that is described in 

“Configure the Base Module” on 

page 14

Содержание SteelCentral SCNP-04280 Series

Страница 1: ...SteelCentral Enterprise NetProfiler Appliance Installation Guide Models SCNP 04280 xx Version 10 16 5 May 2019...

Страница 2: ...n direct indirect consequential and special damages in connection with this document This document may not be copied modified or distributed without the express authorization of Riverbed and may be us...

Страница 3: ...port 9 Cabling to the management network 10 Primary port 10 Remote management 10 Dispatcher Module cabling 10 Power cabling 11 Chapter 4 Configuring the Software 13 Installation time considerations 1...

Страница 4: ...g License Keys 33 Configure Automatic licensing 33 Perform Manual licensing 34 Chapter 8 Adding Expansion Modules 37 Configure the new Dispatcher Module 39 Controls and indicators 41 Front panel 41 Di...

Страница 5: ...how you download new software from the Riverbed Support site and install it in case you need to do so Note Command Line Interface access to NetProfiler is supported for only initial setup and maintena...

Страница 6: ...fety information Refer to the Safety and Compliance Guide if you do not clearly understand the safety information provided in this guide Contacting Riverbed Options for contacting Riverbed include Int...

Страница 7: ...n to management network Access to the network Terminal emulator configured to 9600 baud 8 data bits 1 stop bit no parity and no flow control Configuration information for placing Enterprise NetProfile...

Страница 8: ...t circuits if they are available Console port You perform the initial setup using the console port Verify that you have a terminal server or a system running a terminal emulation program and a cable t...

Страница 9: ...software components and for the appliance to obtain information from servers via scripts UDP 161 snmp Used by NetProfiler to obtain interface information from switches Also management systems use thi...

Страница 10: ...erver IP addresses Applies only if NetProfiler is being synchronized to an external NTP server Enter one or more addresses as a comma separated list Time Zone Flow encryption certificate default or ne...

Страница 11: ...or else copy them directly from the Riverbed licensing web site and then someone must add them to the NetProfiler manually Determine which strategy you are using Will you activate the licenses on the...

Страница 12: ...uded in the same purchase order 3 For each serial number activates the licenses that apply to that serial number Using the Riverbed licensing web site is described in Chapter 7 Configuring License Key...

Страница 13: ...ion from the console port to a terminal server make the connections now Refer to Appendix A Specifications for console port pin assignments If you will temporarily connect to each console port in succ...

Страница 14: ...or additional information complete the installation and then consult the online help for the Configuration General Settings page of the web user interface Dispatcher Module cabling If you are installi...

Страница 15: ...tcher Module to your switch Power cabling If the power cables were not installed when the chassis were mounted in the racks install them at this time If possible plug the two power supplies into diffe...

Страница 16: ...12 SteelCentral Enterprise NetProfiler Appliance Installation Guide Cabling Powercabling...

Страница 17: ...f you need to install and configure new software refer to Chapter 5 Updating NetProfiler Software For instructions on adding an Expansion Module to an existing Enterprise NetProfiler refer to Chapter...

Страница 18: ...latest version from the Support site and perform a full installation This is described in Chapter 5 Updating NetProfiler Software Configure the Base Module You begin to configure the Enterprise NetPr...

Страница 19: ...ic modules of the Enterprise NetProfiler Note If the NetProfiler has Internet access it attempts to download licenses from the Riverbed licensing server You can add or download applicable licenses usi...

Страница 20: ...following prompts For example Welcome to SteelCentral Setup Please enter the PRODUCT CODE SCNP 04280 DP Please enter the new dispatcher module s IP address this device ip prefixlen 10 38 131 50 18 Pl...

Страница 21: ...ress 10 38 129 68 18 Discovered IPv6 network 2600 809 200 1a02 64 Please enter the new expansion module s IP address this device ip prefixlen 10 38 129 68 18 Please enter the Manager UI device s IP ad...

Страница 22: ...18 SteelCentral Enterprise NetProfiler Appliance Installation Guide Configuring the Software ConfigureAdditional ExpansionModule...

Страница 23: ...tProfiler follow the instructions in this chapter Note If the NetProfiler has an Internet connection it will attempt to download licenses from the Riverbed licensing server You can add or download app...

Страница 24: ...ion 1 Make sure to retain the existing boot order after you add the USB key to the boot order From the EXIT menu select Save Changes and Exit and press Enter 8 Select OK in the resulting screen to sav...

Страница 25: ...1 UpdatingNetProfilerSoftware 18 Click Configure Now to complete the configuration 19 When prompted enter a new password for the web user interface After you complete the new software configuration yo...

Страница 26: ...oose a password for the mazu dhcp root and admin shell users Please enter the password Please re enter the password New Settings Product SCNP 04280 IP Address 10 38 128 196 18 Gateway 10 38 128 1 NOTE...

Страница 27: ...n the upper right corner of the front of the chassis During the POST sequence configure the BIOS to boot from an external USB device 4 When the system boots from your USB stick and displays the boot p...

Страница 28: ...o log in to the web user interface as part of the configuration Follow these steps 1 Plug in the bootable USB memory stick 2 Use a terminal emulator program and a console cable to connect a laptop or...

Страница 29: ...n be completed by logging into the UI at https 10 38 128 196 Login as admin admin NOTICE All existing settings and logs will be lost Finish Setup and Reboot yes no yes Working When the Dispatcher Modu...

Страница 30: ...26 SteelCentral Enterprise NetProfiler Appliance Installation Guide Updating NetProfiler Software Install the DispatcherModule...

Страница 31: ...isting environment the user configurations and the historical data are migrated to the new appliance This section contains the following topics How to upgrade your environment on page 28 Supported Mig...

Страница 32: ...ion paths table to prepare for the upgrade process Note Verify that the current appliance and the appliance use the same software version Verify that the current appliance and the new appliance have i...

Страница 33: ...Log in to the user interface of the current appliance and navigate to System Backup 2 Complete the following 1 Select the Exclude flow roll up and identity logs 2 Enter the mazu user name 3 Specify t...

Страница 34: ...the roll up log files from the AN and Expansion modules to the new Base or Expansion modules Do the following 1 Using a command line window run the screen command on the existing appliance to open a...

Страница 35: ...count CREATE USER mazu dst host IP IDENTIFIED BY restore GRANT ALL ON TO mazu dst host IP FLUSH PRIVILEGES 5 Restart the MySQL server services Execute the following command sudo service mysql restart...

Страница 36: ...32 SteelCentral Enterprise NetProfiler Software Installation Guide Upgrading...

Страница 37: ...e Enterprise NetProfiler appliances to run with different features or capacities navigate to the Riverbed licensing web site and assign the licenses to the serial numbers of the products To license a...

Страница 38: ...oducts purchased on the same purchase order as the appliance whose serial numbers you entered 4 Follow the instructions of the licensing wizard to generate the license keys 5 Select to email the licen...

Страница 39: ...es listed on the the Devices tab you cannot verify the Enterprise NetProfiler installation and configuration You must set up at least one data source device preferably all data source devices and then...

Страница 40: ...36 SteelCentral Enterprise NetProfiler Appliance Installation Guide Configuring License Keys Perform Manual licensing...

Страница 41: ...cher Module you can continue to install the remaining Expansion Modules Important Before you begin this process you must identify the currently installed software version Thesoftware version is listed...

Страница 42: ...ame switch on the management network as the UI Module 2 Using a console cable connect a laptop or other device to the Console connector of the Expansion Module 9 Log in at the login prompt using admin...

Страница 43: ...m Information page and verify that the module just added appears under NetProfiler Status with the status of OK Configure the new Dispatcher Module If the configuration will include more than six Expa...

Страница 44: ...the IP address that you assigned to the Base Module and gives the Base Module the IP address that you assigned to the Dispatcher Module in the dialog above The exchange of IP addresses between the Dis...

Страница 45: ...s This chapter describes Controls and indicators on page 41 Mechanical and electrical specifications on page 43 Controls and indicators Front panel The panel near the upper right corner of the front o...

Страница 46: ...s and indicators Callout Name Description A Power Button with green LED System power on green solid on System power off off B Warning LED System Normal off System Warning amber solid on C HDD LED Read...

Страница 47: ...the right end on to the chassis first Mechanical and electrical specifications Rack space The Dispatcher Module requires one rack unit 1U The Analysis and Expansion Modules each requires two rack uni...

Страница 48: ...0Hz 100V to 127V and 200V to 240V 50Hz 60Hz The Dispatcher DP Module consumes up to 232W The Base Module and Expansion Module each consume up to 308W Cooling The Dispatcher DP Module requires approxim...

Страница 49: ...SteelCentral Enterprise NetProfiler Appliance Installation Guide 45...

Страница 50: ...Riverbed Technology 680 Folsom Street San Francisco CA 94107 Fax 415 247 8801 Web http www riverbed com Phone 415 247 8800 Part Number 712 00267 11...

Отзывы: