SteelCentral™ Enterprise NetProfiler Appliance Installation Guide
17
Configure Additional Expansion Module
Configuring the Software
The following is an example of the information required to configure the additional expansion modules:
Welcome to SteelCentral Setup!
Configuring SCNP-04280-EXP with serial number GEHPW0000E732
Press up arrow to access these addresses or ctrl+c to restart
Discovered IPv4 address 10.38.129.68/18
Discovered IPv6 network 2600:809:200:1a02:/64
Please enter the new expansion module's IP address (this device)
ip/prefixlen:
10.38.129.68/18
Please enter the Manager (UI) device's IP address
ip:
10.38.128.196
New Settings:
Product: SCNP-04280-EXP
IP Address: 10.38.129.68/18
Gateway: 10.38.128.1
NOTE: Setup will conclude with a reboot of this SteelCentral device.
NOTICE: All existing settings and logs will be lost.
Finish Setup and Reboot? (yes/no):
yes
Working.....
When the Expansion Module reboots, it communicates with the other Enterprise NetProfiler modules as necessary to
be added to the system.