5IN2933
Step 8: Defining Keyfobs for Output (Gate) Control
Systems equipped with a dedicated wireless expander set to standalone mode can support
up to 200 "standalone keyfobs," each of which can be used to activate up to two outputs for
gate / parking control. For this purpose, the wireless expander can be used in either "bus
mode" (installed inside the main panel enclosure) or in the wireless "standalone mode"
configuration, where it is housed in a separate plastic enclosure, outside of the main panel.
Each standalone keyfob has a dedicated installer-programmable button for each of the 2
possible outputs.
For output control, the standalone keyfobs and wireless expander used are not the same
ones used to operate other functions of the system (arming/disarming, etc.), although the
same keyfob/wireless expander models are used for both purposes.
NOTES:
•
The following procedures are only for standalone keyfobs (for output control)
•
See the packaged wireless expander instructions for standalone usage details
Registering New Keyfobs for Output Control
Each keyfob for output control must be "learned" (registered to the system) by the Grand
Master before it can be used.
➢
To register a keyfob:
1.
At the keypad, enter your Grand Master code, and then press
OK.
2.
Scroll to
Stand Alone KF
(keyfob), and then and press
OK.
3.
Scroll to select the wireless expander ("receiver") that you want to assign the keyfob to
and press
OK.
4.
Scroll to
New Keyfob,
and then press
OK.
5.
Press
OK
to start the Learn mode.
6.
At the 4-buton keyfob, press
for about 3 seconds until the keypad beeps.
7.
Back at the keypad, press
OK
to stop Learn mode.
8.
Repeat from
step 4
for each additional keyfob.