Reference Manual Rev 1.13
004R-646-113
Page 15
Figure 9: Optical Communications attachment
3.11. Connecting Shields
To obtain full EMC or for RFI immunity, cable shields MUST be connected and
the earth lug on the rear of the instrument must be grounded.
Figure 10 illustrates an example of possible connections. Also shown are the
connecting cables restrained using cable ties fastened by screws into the rear of the
unit.