Reference Manual Rev 1.13
004R-646-113
Page 137
Error
Description
Resolution
(E0800) Application settings have been set to
defaults.
Check and re-enter
application settings
(E2000) ADC Out of Range Error. This may be
caused from a broken load cell cable.
Check BUILD:CABLE
setting. Check load cell
cable, wiring, etc.
(E4000) The runtime information has been lost.
Check Zero and tare
settings.
Table 20: Errors: diagnostic
The
E
type error messages are additive. For example if instrument is running off
batteries and the temperature drops, the battery voltage may be too low. The
resulting error messages will be
E 0011
(0001 + 0010). The numbers add in
hexadecimal as follows:
1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - A - B - C - D - E - F
(For example, 2 + 4 = 6, or 4 + 8 = C)