Reference Manual Rev 1.13
Page 112
004R-646-113
Not setpoint 6
14
Not setpoint 5
13
Not setpoint 4
12
Not setpoint 3
11
Not setpoint 2
10
Not setpoint 1
9
Setpoint 8
8
Setpoint 7
7
Setpoint 6
6
Setpoint 5
5
Setpoint 4
4
Setpoint 3
3
Setpoint 2
2
Setpoint 1
1
DLY.ON
: delay before setpoint becomes active.
HLD.OFF
: delay before setpoint becomes inactive.
17.7. Scale Entry/Exit Setpoint Types
The following setpoint types are all based on the status of the indicator.
Scale Ready (SC.REDY)
: Setpoint is active when in the zero band and
stable for longer than the time set in RDY.TIM.
Scale Exit (SC.EXIT)
: Setpoint is active when outside of the zero band and
either a print has occurred or the scale exit (SC.EXIT) special function has
been triggered.
Ready Time (RDY.TIM)
: Time in seconds that the scale must be stable in the zero
band before the scale is ready.