Rinnai 8 ES_FIM
WALL PENETRATIONS
It is
CRITICAL
that any wall penetrations are located correctly.
B
A
iii
i
ii
1.
Select the desired location
i
for the Energysaver Heater.
2. Find the vertical centre line of the appliance
ii
and mark this
location on the wall.
3.
Using Measurements
A
&
B
from Table 1, mark off the arc
centre iii on the wall.
IMPORTANT
The arc centre
iii
corresponds to the pivot point
centre of the telescopic flue elbow on the heater. The
RHFE-308 and RHFE-309 heaters have a fixed length
non-telescopic flue elbow. Hence accurate marking of
the penetration arc and associated area are therefore
especially critical.
G
D
E
C
iii
iv
v
i
ii
4. From the arc axis
iii
use the measurements
C
,
D
&
E
from
Table 1. to draw an arc on the wall.
The lower end point of the arc iv will be the lower limit of the
minimum horizontal and vertical centre of penetration
G
.
The upper end point of the arc v will the be the upper limit of
the minimum horizontal and vertical centre of penetration
G
.
D
E
F
iii
vi
vii
G
i
ii
5. From the arc axis iii use the measurements
F
,
D
&
E
from
Table 1. to draw an arc on the wall.
The lower end point of the arc
vi
will be the lower limit of the
maximum horizontal and vertical centre of penetration
G
.
The upper end point of the arc
vii
will be the upper limit of the
maximum horizontal and vertical centre of penetration
G
.
IMPORTANT
Due to the fixed length non-telescopic flue elbow
of the RHFE-308 and RHFE-309 model heaters
measurements
C
&
F
are the same for these models
only.
viii
i
6. The penetration may be made anywhere within the confines
of the shaded minimum and maximum areas
viii
defined by
the two arcs.
WARNINGS & IMPORTANT INFORMATION
Содержание ENERGYSAVER RHFE-308FTR