UNDER FLOOR FLUE INSTALLATION METHOD
C
E
A
B
H
F
G
D
Y
Total flue length can be up
to nine (9) metres long and
can contain a maximum of
two (2) ESBEND (2x90°)!
Activities for creating a Sideways flue installation:
A
Modify ESDFK for Sideways Installation.
B
Create Penetration in floor
C
Locate Heater.
D
Connect Heater Exhaust.
CAUTION
E
Connect Combustion Air Hose.
CAUTION
F
Installation & fastening of Back Cover Kit (ESBSK)
G
Cut, Fit & Secure Components.
(seal joints as required)
CAUTION
Y
Refer to steps
F
&
G
of Direct & Direct Extended.
(as required)
Z
Finalise Installation & Commissioning of Heater.
The Down and Out flue option allows for a Direct Flue Kit (ESDFK) to face downwards and the flue to be run
vertically though a hole in the floor, and then horizontally to a suitable location outside.
CAUTION
Flue
MUST NOT
terminate under a building.
Flue terminal is
ONLY
available in the horizontal format.
Steps for creating a Under Floor flue installation are as follows:
1.
Using a drill, remove the pop rivet used to fasten the straight flue pipe connection pipe to the flue transition of
ESDFK and remove but
DO NOT
discard the straight flue pipe connection.
2. Fit the elbowed flue pipe connection supplied with the Back Cover kit to the flue transition pushing it fully
home and then fasten in place with the grub screw (supplied) using an Allen key. The grub screw terminates in
a groove in the flue transition. When fastened this prevents accidental dislodgement of the pipe connections.
3.
Refit the straight flue pipe connection to the end of the elbow until it is fully home and then fasten in place
with a 3mm rivet.
CAUTION
Ensure the straight pipe and elbow are securely fastened to the flue transition by the grub
screw and rivets.
Test soundness of the connections by attempting to 'pull apart' the assembled components.
Improper assembly or fastening can result in products of combustion dispersing into the room
being heated which may result in a dangerous condition.
4. Attach the side cover panels from the back cover kit (ESBSK A, B, C, D, E, F, G or H) to the rear of the heater
in accordance with the assembly Instructions supplied with the back cover kit and temporarily position the