REGULATIONS & CLEARANCES
The heater and the flue system shall be installed in accordance with the following:
•
Manufacturer’s Installation Instructions
•
Current AS/NZS 3000, AS/NZS 3500 & AS 5601
•
Local Regulations and Municipal Building Codes
•
Any other relevant Statutory Regulation
IMPORTANT
Before commencing an installation, read the installation sections of the ‘Customer and Installation
Manual’ supplied with the heater. Note that AS/NZS 5601 is referred to in this instruction and
was current at the time of printing, but may have since been superseded. It is the Installer’s
responsibility to ensure that requirements of the current version of AS/NZS 5601 are met.
These components
MUST
be installed, serviced and removed by an Authorised Person!
ONLY
the Rinnai flue
system components specified in this manual
MUST
be used. Components
NOT
specified in this manual, whether
manufactured by Rinnai or otherwise, are
NOT
compatible and
MUST NOT
be used!
Rinnai Energysaver space heater when correctly installed with Rinnai approved flue components are room-sealed
appliances and no internal ventilation is required. The Rinnai Energysaver space heater is fan-assisted. Therefore
the fan assisted flue clearance dimensions from AS/NZS 5601 extract shown on this page
MUST
be used.
The outer plastic section of the Co-Axial Flue complies with temperature hazard requirements and can be installed
with zero clearance to combustible material. Vertical clearances when using a roof terminal (ESROOFCOWL) are
shown in Fig.1. If in doubt contact the Rinnai Australia National Helpline (number on the back page).
Flue terminal
Fan assisted flue appliance only
Gas meter
Electricity meter or fuse box
Mechanical air inlet
Minimum Clearance 500 mm
ESROOFCOWL
Decktite or lead collar flashing
ESPLATE
ESPIPE900
Flue pipe clip supplied with ESPIPE900
Flue pipe clip supplied with ESROOFCOWL
Fan assisted
•
Appliances
up to 50 MJ/h input
200
•
Appliances
over 50 MJ/h input
300
b From the ground, above a balcony or other surface *
300
c Front a return wall or external corner *
300
d
From a gas
meter
(M) (see 5.11.5.9 for vent terminal location of
regulator
)
(see Table 6.6 for New Zealand requirements)
1000
e From an electricity
meter
or fuse box (P) †
500
500
f From a drain pipe or soil pipe
75
g Horizontally from any building structure* = or obstruction facing a terminal
h From any other
flue terminal
, cowl, or combustion air intake †
300
•
Appliances
up to 150 MJ/h input *
300
•
Appliances
over 150 MJ/h input up to 200 MJ/h input *
300
•
Appliances
over 200 MJ/h input up to 250 MJ/h input *
500
•
Appliances
over 250 MJ/h input *
1500
• All fan-assisted
flue appliances
, in the direction of discharge
1500
k From a mechanical air inlet, including a spa blower
1000
• Space heaters up to 50 MJ/h input
150
• Other
appliances
up to 50 MJ/h input
500
•
Appliances
over 50 MJ/h input and up to 150 MJ/h input
1000
•
Appliances
over 150 MJ/h input
1500
1
Where dimensions
c, j
or
k
cannot be achieved an equivalent horizontal distance
measured diagonally from the nearest discharge point of the terminal to the opening
may be deemed by the Technical Regulator to comply.
2
See Clause 6.9.4 for restrictions on a
flue terminal
under a covered area.
3
See Figure J3 for clearances required from a
flue terminal
to an LP Gas
cylinder.
A
flue terminal
is considered to be a source of ignition.
4
Ref.
Item
a
Min. clearances (mm)
Below eaves, balconies and other projections:
j
Horizontally from an openable window, door, non-mechanical air inlet, or any other opening into a building
with the exception of sub-floor ventilation:
Vertically below an openable window, non-mechanical air inlet, or any other opening into a building with the
exception of sub-floor ventilation:
NOTES:
† - Prohibited area below electricity meter or fuse box extends to ground level.
FIGURE 6.2 (in-part) MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS, FAN-ASSISTED FLUE
TERMINALS, ROOM-SEALED APPLIANCE TERMINALS AND OPENINGS OF OUTDOOR APPLIANCES
* - unless
appliance
is
certified
for closer installation
For
appliance
s
not addressed above acceptance should be obtained from the Technical Regulator.
n
Horizontal Clearances (Extract AS/NZS 5601 Fig. 6.2)
NOTE
All Rinnai Energysaver space
heaters are fan assisted (forced
exhaust) appliances.