Rinnai
21
ES_FIM
CUTTING ~ ESDFK, ESPIPE900 & ESROOFCOWL
IMPORTANT
STOP!
When terminating a flue run and installing the wall terminal, follow the instructions
under "Component Assembly & Connection ~ ESROOFCOWL" on page 23 for pipe cutting
procedures.
CAUTION
Cutting is not required for the purposes of joining ESDFK, ESPIPE900 & ESROOFCOWL together
Cutting of the last component in the flue assembly (the component furthest away from the heater)
may be required to achieve the required flue system length. Cutting is also required at a wall
penetration. Cutting for both purposes is described below:
Cutting components to achieve a desired length:
1.
Measure and mark off the outer pipe at the desired length (
AA
).
CAUTION
The minimum length (
ZZ
) of ESDFK when measured from the back plate of the casting
MUST
NOT
be less than 300mm when joining to other components.
2.
Cut the outer pipe to the required length. Take care
NOT
to cut the inner pipe.
3.
From the ‘new’ end of the outer pipe (cut in Step 2.), measure and mark off an additional 12mm on the
inner pipe (
BB
). Cut the inner pipe at this mark. Take care to keep the cut parallel with that of the outer pipe.
4.
Ensure all burrs and swarf are removed from all cut ends.
Cutting components at a wall penetration:
1.
Measure and mark off the outer pipe at a point flush with the surface of the wall penetrated (
CC
) PLUS
an additional 50mm (
DD
)
CAUTION
The minimum length (
ZZ
) of ESDFK when measured from the back plate of the casting
MUST
NOT
be less than 300mm when joining to other components.
2.
Cut the outer pipe to the required length. Take care
NOT
to cut the inner pipe.
3.
From the ‘new’ end of the outer pipe (cut in Step 2.), measure and mark off an additional 12mm on the
inner pipe (
BB
). Cut the inner pipe at this mark. Take care to keep the cut parallel with that of the outer pipe.
4.
Ensure all burrs and swarf are removed from all cut ends.
COMPONENT ASSEMBLY & CONNECTION ~ ESPIPE900
Lubricate O-Rings with the supplied O-ring grease, then fit the female aluminium inner pipe end over the male
inner pipe ends of an adjoining component.
CAUTION
Both the inner and outer pipes of all internal horizontal components
MUST
be secured with
rivets or screws. The joints of PVC outer pipes that are exposed to an outside environment
MUST
be sealed with an appropriate PVC solvent.
2
3
4
Desired length
1
12mm
Minimum ESDFK1
length 300mm
2
3
4
Minimum ESDFK1
length 300mm
Allow 50mm
beyond any
wall penetration *
* Required wall
penetration
1
12mm
INSTALLATION METHODS