Installation & Servicing Instructions Rinnai E-Series
65
NOTICE
i
15
Blocks and Errors
15.1 Error indication (short reference)
A detected error is indicated on the display by means of blocking or error messages. A
distinction should be made between these two messages due to the fact that blocking
can be of a temporary nature, however, error messages are
fi
xed lockings. The control
will try its utmost to prevent locking and will temporarily switch off the unit by blocking
it. The following is a list of some messages.
Blocks
with a number in the last 2 positions.
Block
01:
External safety contact cut off
Block
05:
Outdoor sensor not connected
Block
60:
Incorrect parameter setting of the minimum or maximum power.
Block
67:
A
T has been detected between
fl
ow and return sensor whereas the burner is not in operation.
After
the
T has disappeared the block will clear.
Block
85:
The control has not detected a water
fl
ow. The venting cycle is started.
If during this cycle water
fl
ow is detected, the venting cycle is ended and the burner is released.
Error
with a number in the last two positions.
Error
00:
Poor
fl
ame-forming
Error
02:
no
fl
ame-forming
Error 04: adjustment or error for voltage interruption
Error
05:
adjustment
Error 12: high limit stat
Error
18:
maximum
fl
ow temperature exceeded
Error 19: maximum return temperature exceeded
Error 28: number of revolutions not reported back from fan
Error 69: no or incorrect display
FUSE:
24V fuse defective
The following pages describes more detailed follow up instructions for solving
blockings, errors and practical circumstances. These instructions are only for
licensed professional.