Rinnai I-Series Condensing Boiler Combi Manual
111
Approved System Cleaners:
Fernox F3 Cleaner
Noble Noburst Hydronic System Cleaner
Rhomar Hydro-Solv 9100
Sentinel X400
Approved System Inhibitors:
Noble Noburst AL Inhibitor
Rhomar Pro-tek 922
Sentinel X100
Approved System Antifreezes:
Chem Frost 100%
Fernox Alphi 11
Hall-Chem Solar II
Noble Noburst AL
Rechochem Recofreeze AL
Rhomar RhoGard Mutli-Metal (AL safe)
Sentinel X500
Below is a list of approved system cleaners, inhibitors, and antifreezes for use in hydronic plumbing
systems utilizing Rinnai boilers.
IMPORTANT
If replacing a boiler, add system cleaners while the old boiler is installed and operate the old
boiler for heating for several days to most effectively clean the system.
The Rinnai boiler must be closed off (valved off) from the rest of the system, or not
connected, while cleaners are in the system.
When cleaning is complete, drain the system and then flush with clean water to remove any
sediment.