Page 7 of 24
4. Operation of the pellet control
Once installation is complete you can reconnect your device to the mains.
When using the pellet control, the internal control unit = user board does not
display any information. The pre-stored data of the internal control unit is
automatically accessed by the pellet control.
5. Pellet control functions
The pellet control takes care of the following basic functions of your
pellet stove:
•
Manual operation
•
Automatic operation
•
Standby mode
In addition the following comfort functions are provided:
•
Room set temperature instead of heat output modulation
•
Reduced temperature outside pre-set heating periods
•
Frost protection mode
1
The user can choose a set temperature of ON (AUTOM. TEMP ON) and OFF
(AUTOM. TEMP OFF). This permits a energy savings function that maintains
the system at a lower set temperature outside the heating periods. The set
temperature for OFF works only in automatic operation. An frost protection
temperature can also be entered. If the room temperature falls below this value
the frost protection mode is activated and the system is regulated to "set
temperature, anti-freezing operation". The frost protection mode is only active if
(AUTOM.TEMP OFF) is set to OFF. Otherwise outside the heating periods the
stove is regulated to the set temperature (reduced temperature).
5.1. Room set temperature
The room set temperature can be programmed to the following values (tab. 1):
1
from stove control program version V 1.22A (see operating instruction of the pellet stove)