3. Assembly of the pellet control
3.1. General information
Danger! Remove the power plug of the stove from the wall socket before
working on the device.
When assembling do not allow objects (screws, etc) to fall into the firebox or
hopper - they could block the auger and damage the stove.
Before carrying out work on the
stove, the stove must be switched
off and cooled.
CAUTION: The pellet control must
only be installed by authorized
service technician!
Pellet control symbols
3.2. Wall mounting, cable routing
Remove the front of the housing by pressing sideways on the rear section.
To route the cables upwards break off the press-out points provided on the
housing. To route the cables downwards use the opening in the housing rear
panel. Then mount the housing on the wall using the rear panel.
3.3. Cable specification
To connect the operating unit you will require a commercially available 4-pin
sheave cable. The cable enables all data exchange between the main board
and the pellet control and the electrical supply.