START AQUA 24 BI
14
ENGLISH
15
START AQUA 24 BI
DESCRIPTION
Methane
gas (G20)
Butane
(G30)
Propane
(G31)
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m
3
S
45,67
80,58
70,69
Net Calorific Value
MJ/m
3
S
34,02
116,09
88
Supply nominal pressure
mbar (mm H
2
O)
20 (203,9)
28 - 30 (285,5 - 305,9)
37 (377,3)
Supply minimum pressure
mbar (mm H
2
O)
13,5 (137,7)
START AQUA 24 BI
Burner: number of nozzles
n°
12
12
12
diameter of nozzles
ø mm
1,35
0,77
0,77
CH maximum gas capacity
Sm
3
/h
2,82
kg/h
2,10
2,07
DHW maximum gas capacity
Sm
3
/h
2,82
kg/h
2,10
2,07
CH minimum gas capacity
Sm
3
/h
1,10
kg/h
0,82
0,81
DHW minimum gas capacity
Sm
3
/h
1,10
kg/h
0,82
0,81
CH maximum pressure
(mbar)
9,90
27,60
35,50
(mm H
2
O)
100,95
281,44
362,00
DHW maximum pressure
(mbar)
9,90
27,60
35,50
(mm H
2
O)
100,95
281,44
362,00
CH minimum pressure
(mbar)
1,60
4,80
6,00
(mm H
2
O)
16,32
48,95
61,18
DHW minimum pressure
(mbar)
1,60
4,80
6,00
(mm H
2
O)
16,32
48,95
61,18
MULTIGAS TABLE
Seasonal space heating energy efficiency class
C
Water heating energy efficiency
class
B
Parameter
Symbol
Value
Unit
Parameter
Symbol
Value
Unit
Rated heat output
Prated
24
kW
Seasonal space heating energy
efficiency
η
s
78
%
For boiler space heaters and boiler combination heaters: useful
heat output
For boiler space heaters and boiler combination heaters: useful
efficiency
At rated heat output and high-
temperature regime (*)
P4
23.9
kW
At rated heat output and high-
temperature regime (*)
η
4
80.7
%
At 30% of rated heat output and low-
temperature regime (**)
P1
7.2
kW
At 30% of rated heat output and low-
temperature regime (**)
η
1
81.3
%
Auxiliary electricity consumption
Other parameters
At full load
elmax
10.0
W
Stand-by heat loss
Pstby
180.0
W
At part load
elmin
5.5
W
Pilot flame energy consumption
Pign
-
W
In Stand-by mode
PSB
3.5
W
Annual energy consumption
QHE
88
GJ
Sound power level, indoors
LWA
51
dB
Emissions of nitrogen oxides
NOx
151
mg/kWh
For combination heaters:
Declared load profile
XL
Water heating energy efficiency
η
wh
77
%
Daily electricity consumption
Qelec
0.118
kWh
Daily fuel consumption
Qfuel
26.028
kWh
Annual electricity consumption
AEC
26
kWh
Annual fuel consumption
AFC
19
GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater
inlet).
Содержание START AQUA 24 BI
Страница 1: ...START AQUA 24 BI EN INSTALLER AND USER MANUAL HU TELEP T I S FELHASZN L I K ZIK NYV...
Страница 36: ...START AQUA 24 BI 36 8 7 6 5 3 4 370 50 mm 50 mm 370 mm R M G AC AF...
Страница 37: ...START AQUA 24 BI 37 12 11 10 9 B 13 E A B C D 3 4 1 2 5 3 4 1 2 5 14...
Страница 38: ......
Страница 39: ......
Страница 40: ...Cod 20117085 03 16 Ed 0...