52
RIELLOTECH CLIMA TOP - CLIMA COMFORT
RIELLOTECH CLIMA TOP - CLIMA COMFORT
Operat-
ing line
User
level Function
Default value
Min
Max
Unit
7303(**)
F
Relay output QX23 module 1
OL 7301
-
-
-
-
7307(**)
F
Sensor input BX21 module 1
None ¦ DHW sensor B31 ¦ Collector sensor B6 ¦ Return sensor B7 ¦
DHW circulation sensor B39 ¦ Buffer sensor B4 ¦ Buffer sensor B41 ¦
Flue gas temp sensor B8 ¦ Common flow sensor B10 ¦ Solid fuel
boiler sensor B22 ¦ DHW charging sensor B36 ¦ Buffer sensor B42 ¦
Common return sensor B73 ¦ Cascade return sensor B70 ¦ Swim-
ming pool sensor B13 ¦ Collector sensor 2 B61 ¦ Solar flow sensor
B63 ¦ Solar return sensor B64 ¦ DHW outlet sensor B38 ¦ Solid fuel
boil ret sens B72
-
-
-
-
7308(**)
F
Sensor input BX22 module 1
OL 7307
-
-
-
-
7311(**)
F
Function input H2 module 1
None ¦ Optg mode change HCs+DHW ¦ Optg mode changeover
DHW ¦ Optg mode changeover HCs ¦ Optg mode changeover HC1 ¦
Optg mode changeover HC2 ¦ Optg mode changeover HC3 ¦ Heat
gen lock ¦ Error/alarm message ¦ Consumer request VK1 ¦ Consumer
request VK2 ¦ Release swi pool source heat ¦ Excess heat discharge
¦ Release swi pool solar ¦ Operating level DHW ¦ Operating level HC1
¦ Operating level HC2 ¦ Operating level HC3 ¦ Room thermostat HC1 ¦
Room thermostat HC2 ¦ Room thermostat HC3 ¦ DHW flow switch ¦
Circ’pump thermostat ¦ Dewpoint monitor ¦ Flow temp setp incr
hygro ¦ Boiler return thermostat ¦ Status info suppl source ¦ Charg
prio DHW sol fuel boil ¦ Consumer request VK1 10V ¦ Consumer
request VK2 10V ¦ Pressure measurement 10V ¦ Rel room humidity
10V ¦ Room temp 10V ¦ Flow measurement 10V ¦ Temp measure-
ment 10V
Optg mode change
HCs+DHW
-
-
-
7312(**)
F
Contact type H2 module 1
NC ¦ NO
NO
-
-
-
7314(**)
F
Voltage value 1 H2 module 1
0
0
10
V
7315(**)
F
Funct value 1 H2 module 1
0
-100
500
-
7316(**)
F
Voltage value 2 H2 module 1
10
0
10
V
7317(**)
F
Funct value 2 H2 module 1
100
-100
500
-
7318(**)
F
Temp sensor H2 module 1
None ¦ Solar flow sensor B63 ¦ Solar return sensor B64
None
-
-
-
7321(**)
F
Function input H21 module 1
None ¦ Optg mode change HCs+DHW ¦ Optg mode changeover
DHW ¦ Optg mode changeover HCs ¦ Optg mode changeover HC1 ¦
Optg mode changeover HC2 ¦ Optg mode changeover HC3 ¦ Het
gen lock ¦ Error/alarm message ¦ Consumer request VK1 ¦ Consumer
request VK2 ¦ Release swi pool source heat ¦ Excess heat discharge
¦ Release swi pool solar ¦ Operating level DHW ¦ Operating level HC1
¦ Operating level HC2 ¦ Operating level HC3 ¦ Room thermostat HC1 ¦
Room thermostat HC2 ¦ Room thermostat HC3 ¦ DHW flow switch ¦
Circ pump thermostat ¦ Pulse count ¦ Dewpoint monitor ¦ Flow
temp setp incr hygro ¦ Boiler return thermostat ¦ Status info suppl
source ¦ Charg prio DHW sol fuel boil ¦ Flow measurement Hz ¦
Consumer request VK1 10V ¦ Consumer request VK2 10V ¦ Pressure
measurement 10V ¦ Rel room humidity 10V ¦ Room temp 10V ¦ Flow
measurement 10V ¦ Temp measurement 10V
-
-
-
-
7322(**)
F
Contact type H21 module 1
NC ¦ NO
NO
-
-
-
7324(**)
F
Input value 1 H21 module 1
0
0
1000
-
7325(**)
F
Funct value 1 H21 module 1
0
-100
500
-
7326(**)
F
Input value 2 H21 module 1
10
0
1000
-
7327(**)
F
Funct value 2 H21 module 1
100
-100
500
-
7328(**)
F
Temp sensor H21 module 1
None ¦ Solar flow sensor B63 ¦ Solar return sensor B64
None
-
-
-
7331(**)
F
Function input H22 module 1
OL 7321
-
-
-
-
7332(**)
F
Contact type H22 module 1
NC ¦ NO
NO
-
-
-
7334(**)
F
Input value 1 H22 module 1
0
0
1000
-
7335(**)
F
Funct value 1 H22 module 1
0
-100
500
-
7336(**)
F
Input value 2 H22 module 1
10
0
1000
-
7337(**)
F
Funct value 2 H22 module 1
100
-100
500
-
7338(**)
F
Temp sensor H22 module 1
None ¦ Solar flow sensor B63 ¦ Solar return sensor B64
None
-
-
-