![Riello 20191845 Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/riello/20191845/20191845_manual_1460012077.webp)
79
ENGLISH
Do not touch the refrigerant pipes during and immediately after operation as the refrigerant pipes may be hot or cold, depending on the
condition of the refrigerant flowing through the refrigerant piping, compressor and other refrigerant cycle parts. Burns or frostbite are pos
-
sible if you touch the refrigerant pipes. To avoid injury, give the pipes time to return to normal temperature or, if you must touch them,be
sure to wear protective gloves.
Do not touch the internal parts during and immediately after operation. Touching the internal parts can cause burns. To avoid injury, give
the internal parts time to return to normal temperature or, if you must touch them, be sure to wear protective gloves.
b
CAUTION
Ground the unit.
Grounding resistance should be according to local laws and regulations.
Do not connect the ground wire to gas or water pipes, lightning conductors or telephone ground wires.
Incomplete grounding may cause electric shocks.
- Gas pipes: Fire or an explosion might occur if the gas leaks.
- Water pipes: Hard vinyl tubes are not effective grounds.
- Lightning conductors or telephone ground wires: Electrical threshold may rise abnormally if struck by a lightning bolt.
Install the power wire at least 3 feet (1 meter) away from televisions or radios to prevent interference or noise. (Depending on the radio
waves, a distance of 3 feet (1 meter) may not be sufficient to eliminate the noise.)
Do not wash the unit. This may cause electric shocks or fire. The appliance must be installed in accordance with national wiring regula
-
tions. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to
avoid a hazard.
Do not install the unit in the following places:
−
Where there is mist of mineral oil, oil spray or vapors. Plastic parts may deteriorate, and cause them to come loose or water to leak.
−
Where corrosive gases (such as sulphurous acid gas) are produced. Where corrosion of copper pipes or soldered parts may
cause
refrigerant to leak
.
−
Where there is machinery which emits electromagnetic waves. Electromagnetic waves can disturb the control system and
cause
equipment malfunction.
−
Where flammable gases may leak, where carbon fiber or ignitable dust is suspended in the air or where volatile flammables such as
paint thinner or gasoline are handled. These types of gases might
cause a fire.
−
Where the air contains high levels of salt such as near the ocean.
−
Where voltage fluctuates a lot, such as in factories.
−
In vehicles or vessels.
−
Where acidic or alkaline vapors are present.
This appliance can be used by children 8 years old and above and persons with reduced physical, sensory or mental capabilities or lack
of experience and knowledge if they are supervised or given instruction on using the unit in a safe manner and understand the hazards
involved. Children should not play with the unit. Cleaning and user maintenance should not be
done by children without supervision
.
Children should be supervised to ensure that they do not play with the appliance.
DISPOSAL:
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is nec-
essary. Do not dispose of electrical appliances as municipal waste, use separate collection facilities. Contact your local government for
information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substance
can leak into the groundwater and get into the food chain, damaging your health and well-being.
The wiring must be performed by professional technicians in accordance with national wiring regulation and this circuit diagram. An all-
pole disconnection device which has at least 3mm separation distance in all pole and a residual current device (RCD) with the rating not
exceeding 30mA shall be incorporated in the fixed wiring according to the national rule.
Confirm the safety of the installation area ( walls, floors, etc. ) without hidden dangers such as water, electricity, and gas.Before wiring/
pipes.
Before installation check whether the user's power supply meets the electrical installation requirements of unit ( including reliable ground
-
ing, leakage, and wire diameter electrical load, etc. ). If the electrical installation requirements of the product are not met, the installation
of the product is prohibited until the product is rectified.
When installing multiple air conditioners in a centralized manner, please confirm the load balance of the three-phase power supply, and
multiple units are prevented from being assembled into the same phase of the three-phase power supply.
Product installation should be fixed firmly. Take reinforcem
ent measures, when necessary.
NOTE
About Fluorinated
Gasses
This air-conditioning unit contains fluorinated gasses. For specific information on the type of gas and the amount, please refer to the
relevant label on the unit itself. Compliance with national gas regulations shall be observed.
Installation, service, maintenance and repair of this unit must be performed by a certified technician.
Product uninstallation and recycling must be performed by a certified technician.
If the system has a leak-detection system installed, it must be checked for leaks at least every 12 months. When the unit is checked
for leaks, proper record-keeping of all checks is strongly recommended.