13.3 Operation parameters
This menu is for installer or service engineer reviewing the operation parameters.
At home page, go to ''MENU''>''OPERATION PARAMETER''.
Press ''OK''. There are nine pages for the operating parameter as following. Press ''▼ '', ''▲'' to scroll.
Press"►" and "◄" to check slave units' operation parameter in cascade system. The address code in the upper right corner 00 will change from
"#00" to "#01", "#02" etc. accordingly
OPERATION PARAMETER
#00
OPERATE MODE
COOL
ADDRESS
SV1 STATE ON
ONLINE UNITS NUMBER
1
SV2 STATE OFF
SV3 STATE OFF
PUMP_I ON
1/9
OPERATION PARAMETER
#00
PUMP-C
OFF
ADDRESS
PUMP-S
OFF
PUMP-O
OFF
PUMP-D
OFF
PIPE BACKUP HEATER OFF
TANK BACKUP HEATER ON
2/9
OPERATION PARAMETER
#00
T1 LEAVING WATER TEMP. 35°C
ADDRESS
WATER FLOW 1.72m
3
/h
GAS BOILER OFF
HEAT PUMP CAPACTIY 11.52kW
POWER CONSUM. 1000kWh
Ta ROOM TEMP 25°C
3/9
OPERATION PARAMETER
#00
Tw2 CIRCUIT2 WATER TEMP. 35°C
ADDRESS
TIS’ C1 CLI. CURVE TEMP. 35°C
T5 WATER TANK TEMP. 53°C
TIS2’ C2 CLI. CURVE TEMP. 35°C
TW_O PLATE W-OUTLET TEMP. 35°C
TW_I PLATE W-OUTLET TEMP. 30°C
4/9
OPERATION PARAMETER
#00
Tbt2 BUFFERTANK_LOW TEMP. 35°C
ADDRESS
IDU SOFTWARE 01-09-2019V01
Tbt1 BUFFERTANK_UP TEMP. 35°C
5/9
Tsolar 25°C
OPERATION PARAMETER
#00
COMP.CURRENT
12A
ADDRESS
COMP.FREQENCY 24Hz
ODU MODEL 6kW
COMP.RUN TIME 54 MIN
COMP.TOTAL RUN TIME 1000Hrs
EXPANSION VALVE 200P
6/9
OPERATION PARAMETER
#00
IDU TARGET FREQUENCY 46Hz
ADDRESS
FREQUENCY LIMITED TYPE 5
FAN SPEED 600R/MIN
SUPPLY VOLTAGE 230V
DC GENERATRIX VOLTAGE 420V
DC GENERATRIX CURRENT 18A
7/9
OPERATION PARAMETER
#00
TW_I PLATE W-INLET TEMP. 30°C
ADDRESS
T2 PLATE F-OUT TEMP. 35°C
TW_O PLATE W-OUTLET TEMP. 35°C
T2B PLATE F-IN TEMP. 35°C
Th COMP. SUCTION TEMP. 5°C
Tp COMP. DISCHARGE TEMP. 75°C
8/9
OPERATION PARAMETER
#00
T4 OUTDOOR AIR TEMP. 5°C
ADDRESS
TF MODULE TEMP. 55°C
T3 OUTDOOR EXCHARGE TEMP. 5°C
P1 COMP. PRESSURE 2300kPa
ODU SOFTWARE 01-09-2018V01
HMI SOFTWARE 01-09-2018V01
9/9
NOTE
The power consumption parameter is optional. If some parameter is not be activated in the system, the parameter will show "--".
The heat pump capacity is for reference only, not used to judge the ability of the unit. The accuracy of sensor is ±1°C The flow rates parameters
are calculated according to the pump running parameters,the deviation is different at different flow rates,the maximum of deviation is 15%.The
flow parameters are calculated according to the electrical parameters of the pump operation.
The operating voltage is different and the deviation is different.
The display valve is 0 when the voltage is less than 198V.