5.1
WATER FLOW TEMP.
Enable or disable the WATER FLOW TEMP.:0=NON,1=YES
1
0
1
1
/
5.2
ROOM TEMP.
Enable or disable the ROOM TEMP.:0=NON,1=YES
0
0
1
1
/
5.3
DOUBLE ZONE
Enable or disable the ROOM THERMOSTAT DOUBLE
ZONE:0=NON,1=YES
0
0
1
1
7
6.1
ROOM THERMOSTAT
The style of room thermostat
0=NON; 1=MODE SET; 2=ONE ZONE; 3=DOUBLE ZONE
0
0
3
1
/
7.1
dT1_IBH_ON
The temperature difference betw een T1S and T1 for starting the
backup heater
5
2
10
1
°C
7.2
t_IBH_DELAY
The time that the compressor has run before the first backup heater
turns on
30
15
120
5
min
7.3
T4_IBH_ON
The ambient temperature for starting the backup heater
-5
-15
10
1
°C
7.4
dT1_AHS_ON
The temperature difference betw een T1S and T1B for turning the ad
-
ditional heating source on
5
2
10
1
°C
7.5
t_AHS_DELAY
The time that the compressor has run before starting the additional
heating source
30
5
120
5
min
7.6
T4_AHS_ON
The ambient temperature for starting the additional heating source
-5
-15
10
1
°C
7.7
IBH_LOCATE
IBH/AHS installation location PIPE LOOP=0; BUFFER TANK=1
0
0
0
0
°C
7.8
P_IBH1
Power input of IBH1
0
0
20
0.5
kW
7.9
P_IBH2
Power input of IBH2
0
0
20
0.5
kW
7.10
P_TBH
Power input of TBH
2
0
20
0.5
kW
8.1
T1S_H.A_H
The target outlet w ater temperature for space heating w hen in holiday
aw ay mode
25
20
25
1
°C
8.2
T5S_H.A_DHW
The target outlet w ater temperature for domestic hot water heating w
hen in holiday aw ay mode
25
20
25
1
°C
12.1
PREHEATING FOR FLOOR
T1S t_FIRSTFH
The setting temperature of outlet w ater during first preheating for floor
25
25
35
1
°C
12.3
t_FIRST-H
The time last for preheating floor
72
48
96
12
hour
12.4
t_DRYUP
The day for warming up during floor drying up
8
4
15
1
day
12.5
t_HIGHPEAK
The continue days in high temperature during foor drying up
5
3
7
1
day
12.6
t_DRYD
The day of dropping temperature during floor drying up
5
4
15
1
day
12.7
T_DRYPEAK
The target peak temperature of water flow during foor drying up
45
30
55
1
°C
12.8
START TIME
The start time of floor drying up
Hour: the
present time
(not on the
hour +1, on
the hour +2)
Minute 00
0:00
23:30
1/30
h/min
12.9
START DATE
The start date of floor drying up
the present
date
1/1/2000
31/12/2099 1/1/2001
d/m/y
13.1
AUTO RESTART COOL/
HEAT MODE
Enable or disable the auto restart cooling/heating mode.
0=NON,1=YES
1
0
1
1
/
13.2
AUTO RESTART DHW
MODE
Enable or disable the auto restart DHW mode.
0=NON,1=YES
1
0
1
1
/
14.1
POWER INPUT LIMITATION The type of power input limitation, 0=NON, 1~8=TYPE 1~8
0
0
8
1
/
15.1
ON/OFFM1 M2
Define the function of the M1M2 switch;
0= REMOTE ON/OFF,1= TBH ON/OFF, 2= AHS ON/OFF
0
0
2
1
/
15.2
SMART GRID
Enable or disable the SMART GRID;
0=NON,1=YES
0
0
1
1
/
15.3
T1b (Tw2)
Enable or disable the T1b(Tw 2) ;
0=NON,1=YES
0
0
1
1
/
15.4
Tbt1
Enable or disable the Tbt1;
0=NON,1=YES
0
0
1
1
/
15.5
Tbt2
Enable or disable the Tbt2;
0=NON,1=YES
0
0
1
1
/
15.6
Ta
Enable or disable the Ta;
0=NON,1=YES
0
0
1
1
/
15.7
SOLAR INPUT
Choose the SOLAR INPUT;
0=NON, 1=CN18Tsolar, 2=CN11SL1SL2
0
0
2
1
/
15.8
F-PIPE LENGTH
Choose the total length of the liquid pipe (F-PIPE LENGTH);
0=F-PIPE LENGTH <10m,1=F-PIPE LENGTH
≥
10m
0
0
1
1
/
15.9
dTbt2
The temperature difference for starting the unit (Tbt2)
15
0
50
1
°C
15.10
RT/Ta_PCB
Enable or disable the RT/Ta_PCB;
0=NON,1=YES
0
0
1
1
/
16.1
PER_START
Start-up percentage of multiple units
10
10
100
10
%
16.2
TIME_ADJUST
Adjustment time of adding and subtracting units
5
1
60
1
min
16.3
ADDRESS RESET
Reset the address code of the unit
FF
0
15
1
/
17.1
HMI SET
Choose the HMI;
0=MASTER,1=SLAVE
0
0
1
1
/
17.2
HMI ADDRESS FOR BMS
Set the HMI address code for BMS
1
1
16
1
/