![Riello 20127839 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/riello/20127839/20127839_installation-and-technical-service-instructions_1460009016.webp)
16
INStAllAtION
—
pour water into the condensate tray
—
check that it flows out correctly through the drainage pipe
—
reposition the filters
—
close the panel
2.13
Wiring diagram
Heat exchanger sensor
Indoor air temperature sensor
Emergency switch
Horizontal
swing motor
M
Fuse
1
SW1
CN7
T3
.15
A/25
0VAC
To outdoor unit
Terminal block
1(N)
(C)
3
(L)
2
W
B
Y/G
GND
CN14
CN6
Vertical swing
motor
CN11
CN5'
R
C0N1
(L)
CN21
N
S
CN51
CN9
CN52
CN23
CN34
WIFI
Room card
CN5
DC Fan motor
C0N2
C0N3
CN11’
Display
SW2
1 2 3 4
ON
CN1
CN36
Remote controller receiver
2.14
Electrical connection
AMW P
it leaves the factory completely wired, and only requires
a connection to the outdoor unit.
ON
OFF
—
position the system's main switch in the "OFF" position.
To access the terminal board:
1
Electric panel access panel
2
Connection cable
3
Terminal board cover panel
4
Terminal blocks
1
2
3
4
—
lift the front panel
—
unscrew the fastening screw
—
remove the electric panel access panel
9
The electric panel access panel is wired to the electronic
board, so it must not be completely removed. Pay particular
attention not to disconnect or tear off the wire.