76
SCT-1100 Weight Transmitter
The purpose is to create a label directly onto the instrument by configuring the following parameters. Once the
programming is complete, the label must be downloaded to the printer and saved in its permanent memory. See
Parameter
Description
Enables the default setting in each parameter
NOTE: This parameter is not displayed in the secondary mode.
Select the fields to be printed:
= gross weight;
= net weight;
= tare weight
NOTE: This parameter is not displayed in the secondary mode.
Select the font type:
= the data is printed using the font programmed in the
step
= the data is printed using the font programmed in the
step
Set the label width:
Enter a three digit value, expressed in mm (default 063)
Set the label height:
Enter a three digit value, expressed in mm (default 080)
Select the font for character 1 associated data (default
)
Select the font for character 2 associated data (default
)
For each character type one of the following fonts can be set:
Example: To print 4 heading lines, with the first
two double the height in respect to he second
two, GROSS, TARE, NET, DATE and TIME
Program the heading:
Line 1 and Line 2 = Char 2
Line 3 and Line 4 = Char 1
Char.t = Char 1
Char 1 = Font.3
Char 2 = Fon.3d
Resulting Label
Set the distance data is printed from the label upper margin;
Enter a three digit value, expressed in mm (default 010)
Set the distance data is printed from the label left margin;
Enter a three digit value, expressed in mm (default 004)
Table 6-21. Label Creation Parameters
Font
Parameter
Font Style
(width x height)
1 x 1.5 mm
1 x 3 mm
1.5 x 2.5 mm
1.5 x 5 mm
2 x 3 mm
2 x 6 mm
3 x 4 mm
3 x 8 mm
4 x 6 mm
4 x 12 mm
DIMENSION = ChAr 2
Æ
DIMENSION = ChAr 1
Æ
HEADING 1
HEADING 2
HEADING 3
HEADING 4
Содержание SCT-1100
Страница 1: ...SCT 1100 Advanced Series Weight Transmitter Technical Manual PN 185658 Rev A October 31 2017...
Страница 86: ...82 SCT 1100 Weight Transmitter...