Communications
67
2. Compile the parameters table.
The string length is 49 chars (from 0 to 48 included), however, the field
is set to 48 because to allow
for the character terminator
6.7
Primary, Secondary and Repeater Mode Configurations
These configurations are possible only if in the instrument is in the secondary mode.
6.7.1
Repeaters
The RepeaterDC
configuration is designed to control one or more remote displays connected via an
RS-232 or RS-485 and to coordinate communications over the single serial line.
Packets are sent from the “Master” to the remote displays at 100ms intervals; one ID per loop and no acknowledge
message will be received.
When the number of scales is defined in the “Master”, the rEPE.dC command will return scale values for each as
well as the sum for all connected scales. To limit the scale values returned, or remove readings from a particular
scale, use the
parameter to adjust.
REPE.6
Simple repetition of the DFW’s screen in the SCT. Can be used both in 232 and in 485. The repeater keys are disabled.
Parameter
LCD Text
Value
Remote scale terminator
010
Remote scale weight position
10
Remote scale weight length
10
Remote scale tare position
23
Remote scale tare length
10
Remote scale tare type position
21
Remote scale sting length
48
Table 6-10. Parameters Table
SCT-1100 repeater
:
X
/
Table 6-11. Analog Cells
SCT-1100 repeater
:
X
Table 6-12. Digital Cells
Note