Operation
27
to the minimum time length of the impulse expressed in hundredths of seconds.
3. Press
or
until the desired value displays. See
for a list of settable values.
4. Press
to confirm. The instrument returns to the weigh mode.
The peak detection function sensitivity is dependent on the parameter set. The higher the number of samplings, the
greater the sensitivity. If an unexpected peak is detected immediately, decrease the sensitivity.
Example: If 0.000 kg is on the load cell of 20 kg (350
Ω
), and the sampling time is equal to 1, when the
peak function is enabled, 0.005 kg displays.
3.10.10Horizontal Totalizer
The horizontal totalizer is used to obtain a sum weight of multiple weighings.
1. Press
or
until the desired value displays.
•
– (normal) for each accumulation operation, weigh number and the net weight total display
before the data prints
•
– (fast) only
displays before printing
•
– (automatic) a stable weight is automatically acquired,
displays and the data is printed
2. Press
to
confirm.
displays.
3. Press
to enter the menu.
4. Set the number of consecutive totalizations (0-63) after which the total is automatically printed and reset.
Press
to select the digit to be modified and
or
to increase or decrease the digit. Press
to
confirm. A setting of 0 disables the function.
Operation
1. Load the weight on the scale and press
(if the automatic totalization is not set). The weight is
accumulated in two total levels, a partial total and a general total. To totalize the net weight must:
• be at least one division with normal or fast totalization
• be at least ten divisions with automatic totalization
2. Press
again (without re-enabling the totalization).
• in normal totalization it is possible to momentarily view the number of weighings completed and the
partial net total. If the accumulated values is more than five digits, the visualization takes place in two
stages.
• in fast totalization the error message
displays.
• if the gross weight is equal to zero,
displays
• if the net weight is equal to zero,
displays
Totalization with Printing
If a printer is configured, with each press of
the data programmed in
) is sent to the printer. For example: weighing number, gross weight, tare weight, net weight.
Time in
1/100 sec
Sample per
Second
Acquired
Values
Mediated
Values
1
400
1
1
2
200
1
1
3
100
1
1
4
100
4
2
5
50
4
2
10
25
4
2
20
12
4
2
50
6
4
2
100
6
8
2
127
6
12
2
Table 3-4. Sample Times in Peak Weight Detection
Содержание SCT-1100
Страница 1: ...SCT 1100 Advanced Series Weight Transmitter Technical Manual PN 185658 Rev A October 31 2017...
Страница 86: ...82 SCT 1100 Weight Transmitter...
Страница 87: ......