Configuration/Dealer Settings
23
Auto
adjusting
Spec
Min
Max
0000:
3.46
4.00
0001:
3.00
3.46
0010:
2.59
3.00
0011:
2.25
2.59
Spec
Min
Max
0100:
1.95
2.25
0101:
1.69
1.95
0110:
1.46
1.69
0111:
1.27
1.46
Spec
Min
Max
1000:
1.09
1.27
1001:
0.95
1.09
1010:
0.82
0.95
1011:
0.71
0.82
Spec
Min
Max
1100:
0.61
0.71
1101:
0.53
0.91
1110:
0.46
0.53
1111:
0.40
0.46
32
1010
Calibration/Default
Spec/Spec 142
Mode Protected by
Span
0:
Yes
1:
No
Low Battery (turn on
annunciator)
0:
Yes
1:
No
Auto Exit from Part
Accumulation and
Reduction Mode
0:
No
1:
Yes
Scale Connected to
the Cable Port 2
Connector
0:
No
1:
Yes
CAUTION
:
If you are
not connecting a scale
to this connector,
make sure that you
select No. Selecting
Yes can damage the
console’s electronic
components.
33
0____
Over Weight Mask
at:
0:
+1d
1:
+9d
Weight Decimal Point Position (Cable Port 2, Scale 2 or 3)
000:
00000
011:
00.000
001:
0000.0
100:
0.0000
010:
000.00
34
0000
(For Scale 1)
0:
For std/normal load
cell
1:
For abnormal load
cell with too large
offset
A/D Board (Scale 1) Vibration Sensitivity
Settings
00:
Normal
01:
Prevent from small vibration/fast change in
display
10:
Prevent from medium vibration
11:
Prevent from large slow change in display
35
0000
(For Scale 2)
0:
For std/normal load
cell
1:
For abnormal load
cell with too large
offset
A/D Board (Scale 2) Vibration Sensitivity
Settings
00:
Normal
01:
Prevent from small vibration/fast change in
display
10:
Prevent from medium vibration
11:
Prevent from large slow change in display
36
__00
Minimum Display (Cable Port 2, Scale 2 or 3)
00:
2
01:
1
10:
5
11:
10
A/D Board (Cable Port 2, Scale 2 or 3) Vibration
Sensitivity Settings
00:
Normal
01:
Prevent from small vibration/fast change in
display
10:
Prevent from medium vibration
11:
Prevent from large slow change in display
37
1001
Load Cell Sensitivities Selection (mV/V)—Cable Port 2, Scale 2 or 3
Spec
Min
Max
0000:
3.46
4.00
0001:
3.00
3.46
0010:
2.59
3.00
0011:
2.25
2.59
Spec
Min
Max
0100:
1.95
2.25
0101:
1.69
1.95
0110:
1.46
1.69
0111:
1.27
1.46
Spec
Min
Max
1000:
1.09
1.27
1001:
0.95
1.09
1010
:
0.82
0.95
1011:
0.71
0.82
Spec
Min
Max
1100:
0.61
0.71
1101:
0.53
0.91
1110:
0.46
0.53
1111:
0.40
0.46
Specification
Default
Bit 3
Bit 2
Bit 1
Bit 0
Table 5-2. Applicable IQ9500 Weight and Measurement Specifications (142 Settings) (Continued)