22
IQ9500 Installation Manual
23
0000
Display Resolution for Scales 1, 2, 3, and 4
00:
1/10,000
01:
1/5,000
10:
1/2500
11:
Not used
Zero Setting Range
00:
+Unlimited/–10% FS
01:
±2% FS
10:
±10% FS
11:
Not available
24
0001
Masked Display at
Minus Weight
0:
Gross
1:
Net
Display at Minus
Weight
0:
Minus display
1:
Masked
Zero Lamp Lighting
Method
0:
Gross
1:
Net
Low Battery (turn off
display)
0:
No
1:
Yes
25
00_0
Scale Starting
Method
0:
Automatic
1:
Manual (must
press
REZERO
key)
IR Mode Protected by
Span Switch
0:
No
1:
Yes
Scale Type
0:
Single scale
1:
Dual scale
NOTE:
If you are not
connected to a
dual-platform IQ9500,
or do not have two
scales wired into
Cable Port 1, then this
bit needs to be set to 0
(single scale).
Selecting 1 (dual
scale) can damage the
console’s electronic
components.
Gross Mode Available
0:
Yes
1:
No
26
0000
Zero Tracking When
Tare
0:
Yes
1:
No
Rezero with a Tare
Weight
0:
Yes
1:
No
Initial Start Range
00:
+Unlimited/–10% FS
01:
±2% FS
10:
±10% FS
11:
Not available
27
0100
Comma Display
0:
No
1:
Yes
Digital Tare Setting
0:
No
1:
Yes
Tare Range
00:
100% FS
01:
50% FS
10:
5% FS
11:
Not available
28
0000
Auto Tare Clear
When Rezero
0:
No
1:
Yes
Automatic Unit Weight Clear Condition
00:
Over net 5d and gross 21d and weight
stable
01:
Greater than or equal to net 1d and weight
stable
10:
Greater than or equal to net 1d and quantity
greater than zero and weight stable
Automatic Unit Weight
Clear
0:
No
1:
Yes
29
0000
Digital Tare
Rounding
0:
Tare exactly
1:
Round to nearest
increment
Tare Value Exchange
with TARE key
0:
Yes
1:
No
Tare Addition
0:
Yes
1:
No
Tare Subtraction
0:
Yes
1:
No
30
1001
Load Cell Sensitivities Selection (mV/V)—Scale 1
Auto
adjusting
Spec
Min
Max
0000:
3.46
4.00
0001:
3.00
3.46
0010:
2.59
3.00
0011:
2.25
2.59
Spec
Min
Max
0100:
1.95
2.25
0101:
1.69
1.95
0110:
1.46
1.69
0111:
1.27
1.46
Spec
Min
Max
1000:
1.09
1.27
1001:
0.95
1.09
1010:
0.82
0.95
1011:
0.71
0.82
Spec
Min
Max
1100:
0.61
0.71
1101:
0.53
0.91
1110:
0.46
0.53
1111:
0.40
0.46
31
1001
Load Cell Sensitivities Selection (mV/V)—Scale 2
Specification
Default
Bit 3
Bit 2
Bit 1
Bit 0
Table 5-2. Applicable IQ9500 Weight and Measurement Specifications (142 Settings) (Continued)