¾
Mount the Reception Paper Guide to the APES-14 Reception top with the 2
supplied 3-winged knobs. Push the assembly to its back-most setting. This is the
standard location for the Paper Guide. The Paper Stop adjustment is covered
later in this manual. See Figure J.
Fig. J
Reception Paper Guide and Paper Stop
5) How to determine if my HD-6500 or HD-7500 is UL or not:
Prior to both machines being granted Underwriters Laboratories (UL) status,
the foot pedal receptacles were wired differently. It is very important that
you identify your machine before continuing. We have provided one Non-
UL foot pedal patch cable that modifies your Non-UL HD punch to be
compatible with the APES-14 machine. See Figure K.
Fig. K
Failure to uses these patch cable in the correct configuration will make the APES-14
temporarily inoperable. If your machine has had a circuit board upgrade, follow the UL
setup. First identification; Non-UL machines have fuses, UL machines do not. See
Figure L & M.
Fig. L Non-UL Machine Fig. M UL Machine