background image

3

1.  WARNINGS 

Pay Attention to these Terms

A

DANGER

Indicates the presence of immediate hazards which will cause severe personal injury, death or substantial 

property damage if ignored.

A

WARNING 

I

ndicates the presence of hazards or unsafe practices which could cause severe personal injury, death or 

substantial property damage if ignored.

A

CAUTION

Indicates the presence of hazards or unsafe practices which could cause minor personal injury or product 

or property damage if ignored.

CAUTION

CAUTION used without the warning alert symbol indicates a potentially hazardous condition which could 

cause minor personal injury or product or property damage if ignored.

NOTE

Indicates special instructions on installation, operation, or maintenance which are important but not related 

to personal injury hazards.

A

DANGER: 

Serious bodily harm or death can result if 

this pump and motor is not installed and used correctly.

A

WARNING:

 Risk of electrical shock. More than one 

disconnect  switch  may  be  required  to  de-energize  the 

equipment before servicing.

A

WARNING:

 This pump and motor is intended for use 

in swimming pool applications.

A

WARNING:

 Most states and local codes regulate the 

construction, installation, and operation of public pools 

and spas, and the construction of residential pools and 

spas. It is important to comply with these codes, many 

of which directly regulate the installation and use of this 

product. Consult your local building and health codes 

for more information.

A

WARNING:

 To reduce the risk of injury, do not permit 

children  to  use  this  product  unless  they  are  closely 

supervised at all times.

A

WARNING:

  When  setting  up  pool  water  turnovers 

or  flow  rates,  the  operator  must  consider  local  codes 

governing turnover as well as disinfectant feed ratios.

A

WARNING:

  DO  NOT  increase  pump  size,  this  will 

increase the flow rate through the system and exceed 

the maximum flow rate stated on the drain cover.

A

WARNING:

  Before  installing  this  product,  read 

and follow all warnings notices and instructions in this 

manual. Failure to follow warnings and instructions can 

result in severe injury, death, or property damage. Please  

call 1-877-213-3726 or refer to www.raypak.com for more 

information related to this product.

A

WARNING:

  Improper  installation,  adjustment, 

alteration, service, or maintenance can cause property 

damage, personal injury or loss of life. 

A

WARNING:

 A  pool  or  spa  pump  must  be  installed 

by  a  qualified  pool  and  spa  service  professional  in 

accordance  with  the  National  Electrical  Code  and 

all  applicable  local  codes  and  ordinances.  Improper 

installation may cause and electrical hazard which could 

result in death or serious injury to pool users, installers, 

or  others  due  to  electrical  shock,  and  also  cause 

property damage.

A

WARNING:

 Pumps are not a substitute for properly 

installed and secured pool drain covers. Refer to local 

codes and requirements as appropriate. An ANSI/ASME 

A112.19.8  approved  anti-entrapment  drain  cover  must 

be used for each drain. Pools and spas should utilize a 

minimum of 2 drains per pump. If a drain cover becomes 

loose,  broken,  or  is  missing,  close  the  pool  or  spa 

immediately  and  shut  off  the  pump  until  an  approved 

anti-entrapment  drain  cover  is  properly  installed  with 

the manufacturer's supplied screws.

A

WARNING:

  Pump  suction  is  hazardous  and  can 

trap and drown or disembowel bathers. Do not use or 

operate swimming pools, spas, or hot tubs if a suction 

outlet cover is missing, broken, or loose.

A

DANGER: 

Hazardous  suction  can 

trap hair or body parts, causing severe 

injury or death. Do not block suction.

2.  IMPORTANT SAFETY INSTRUCTIONS.  

READ AND FOLLOW ALL INSTRUCTION. 

APPROVED 

UNCONTROLLED DOCUMENT IF PRINTED 

 

Содержание Raypak RCAGP100

Страница 1: ...ed and experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not...

Страница 2: ...Up section Added three bullet points to Priming section Replaced Figure 3 with new illustration which contains the speed selector switch Item 11 Added Item 11 to Table C TABLE OF CONTENTS 1 WARNINGS 3...

Страница 3: ...as well as disinfectant feed ratios AWARNING DO NOT increase pump size this will increase the flow rate through the system and exceed the maximum flow rate stated on the drain cover AWARNING Before in...

Страница 4: ...o avoid dangerous or fatal electrical shock turn OFF power to the pump before working on electrical connections NOTE Always turn off all power to the pool pump before installing the cover or working o...

Страница 5: ...system shall be constructed so that it shall not allow for separate or independent shutoff or isolation of each drain More than one pump can be connected to a single suction line as long as the requi...

Страница 6: ...erious or fatal electrical shock hazard DO NOT ground to a gas supply pipe line AWARNING The system s centrifugal pump operates with electrical voltage and can generate both vacuum and pressure in the...

Страница 7: ...ASE ALL PRESSURE from the pump and the piping system before proceeding NEVER tighten or loosen screws while the pump is operating Do not block pump suction AWARNING Do not block pump suction To do so...

Страница 8: ...water pressure resulting in damage to the pump casing impeller and mechanical seal Such damage will not be covered under warranty 6 GENERAL MAINTENANCE AWARNING To prevent damage to the pump and for p...

Страница 9: ...eal Low Pump Capacity Valve in suction or discharge line is partly closed Open or replace the valve Suction or discharge line is partly plugged Clear the obstruction Suction or discharge line is too s...

Страница 10: ...OVER RCAGP 080337F 2 3 3 KIT O RING FOR LID RCAGP 080338F 4 KIT BASKET WITH HANDLE RCAGP 080339F 5 KIT 1 5 NPT UNION KIT RCAGP 080340F 6 7 7 KIT 1 5 UNION O RING RCAGP 080341F 8 KIT PUMP BASE RCAGP 08...

Страница 11: ...tered with Raypak www raypak com warranty then the Applicable Warranty Period is one 1 year from the Effective Date for the PUMP and component parts LABOR AND SHIPPING COSTS This Limited Warranty does...

Страница 12: ...TO MAKE ANY OTHER WARRANTIES ON RAYPAK S BEHALF ANY IMPLIED WARRANTIES INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYOND THE APPLICABLE WARRANTY PERIOD SPECIFIED IN...

Страница 13: ...l entretien de ce type d quipement et de ses composantes connexes Dans certaines r gions les techniciens d entretien pour ce type d quipement doivent d tenir une licence Les personnes non qualifi es...

Страница 14: ...on D marrage Ajout de trois puces la section Amor age Remplacement de la figure 3 par une nouvelle illustration qui contient le s lecteur de vitesse article 11 Ajout de l article 11 au tableau C TABLE...

Страница 15: ...d ajout de produit d sinfectants AAVERTISSEMENT N augmentez PAS la capacit de la pompe cela augmentera le d bit travers le syst me et d passera le d bit maximal indiqu sur le couvercle du drain AAVERT...

Страница 16: ...ique dangereux ou mortel coupez l alimentation de la pompe avant de toucher les connexions lectriques NOTE coupez toujours l alimentation de la pompe de piscine avant d installer le couvercle d aspira...

Страница 17: ...x convergent dans une seule conduite d aspiration celle ci peut tre quip e d une vanne coupant l alimentation des deux drains la pompe Le syst me doit tre construit de fa on ce qu il ne soit pas possi...

Страница 18: ...en courant alternatif Le fait de ne pas mettre le moteur la terre peut entra ner un risque de choc lectrique grave ou mortel NE PAS mettre la terre un tuyau d alimentation en gaz r la masse entra ne...

Страница 19: ...ib rez tout l air du filtre et du syst me de tuyauterie voir les instructions relatives au filtre ci dessous Dans un syst me d aspiration inond source d eau sup rieure la pompe la pompe s amorce par e...

Страница 20: ...re pour serrer le couvercle Mettez sous tension le disjoncteur de la maison Facultatif R glez l horloge de la piscine l heure correcte D marrez la pompe en basculant son interrupteur d alimentation su...

Страница 21: ...uvrir ou remplacer la vanne La vanne dans la conduite d aspiration ou de d charge est partiellement bloqu e liminer l obstruction La conduite d aspiration ou de d charge est sous dimensionn e Refaire...

Страница 22: ...COVER RCAGP 080337F 2 3 3 KIT O RING FOR LID RCAGP 080338F 4 KIT BASKET WITH HANDLE RCAGP 080339F 5 KIT 1 5 NPT UNION KIT RCAGP 080340F 6 7 7 KIT 1 5 UNION O RING RCAGP 080341F 8 KIT PUMP BASE RCAGP 0...

Страница 23: ...rranty la p riode de garantie applicable est d un an compter de la date d entr e en vigueur pour la pompe et les composants CO TS DE MAIN D UVRE ET D EXP DITION Cette garantie limit e NE couvre PAS le...

Страница 24: ...E RAYPAK AUCUNE GARANTIE IMPLICITE NOTAMMENT DE QUALIT MARCHANDE OU D APTITUDE R PONDRE UN USAGE PARTICULIER NE SAURAIT TRE INTERPR T E DANS UN SENS QUI D PASSE LES P RIODES DE GARANTIE APPLICABLES NO...

Отзывы: