7.  TROUBLESHOOTING

Problem

Cause

Action

Motor Does Not Start

Switch or circuit breaker is in ON position

Turn to ON position

Fuses blown or thermal overload open

Replace fuses

Locked motor shaft

Replace the pump

Motor windings burned out

Replace the pump

Defective starting switch inside single-phase motor

Replace the pump

Disconnected or defective wiring

Repair the wiring

Low voltage

Call an electrician

Pump Does Not Reach Full 

Speed

Low voltage

Call an electrician

Pump connected to the wrong voltage

Call an electrician

Motor Overheats (Circuit 

Breaker Trips)

Low voltage

Call an electrician

Motor windings connected to the wrong voltage on dual-

voltage models

Call an electrician

Inadequate ventilation

Relocate the pump

Pump Delivers No Water

Pump is not primed

Prime the pump

Closed valve in the suction or discharge line

Open the valve

Leakage or air into suction system

Call a plumber

Impeller is clogged

Disassemble the pump

Leakage Of Water At Shaft

Shaft seal requires replacement

Replace the seal

Low Pump Capacity

Valve in suction or discharge line is partly closed

Open or replace the valve

Suction or discharge line is partly plugged

Clear the obstruction

Suction or discharge line is too small

Re-plumb, use a larger pipe 

diameter

Plugged basket in skimmer or hair and lint strainer

Clean the basket

Dirty filter

Clean the filter

Impeller clogged

Disassemble the pump

High Pump Pressure

Discharge valve or inlet fittings closed too much

Readjust or replace

Return line is too small

Re-plumb, use a larger pipe 

diameter

Dirty filter

Clean the filter.

Noisy Pump And Motor

Plugged basket in skimmer or hair in lint strainer

Clean the basket

Worn motor bearings

Replace the pump

Valve in suction line is partly closed

Readjust the valve

Suction line is partly plugged

Clean or remove the plug

Vacuum hose is plugged or too small

Clean or remove the plug

Pump not supported properly

Examine or replace the base

Air Bubbles At Inlet Fittings

Leakage of air into suction line at connections or valve stem

Call a plumber

Cover gasket of hair and lint strainer needs cleaning

Clean the cover gasket

Low water level in pool

Refill pool

Table B. 

Troubleshooting Guide

APPROVED 

UNCONTROLLED DOCUMENT IF PRINTED 

 

Содержание Raypak RCAGP100

Страница 1: ...ed and experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not...

Страница 2: ...Up section Added three bullet points to Priming section Replaced Figure 3 with new illustration which contains the speed selector switch Item 11 Added Item 11 to Table C TABLE OF CONTENTS 1 WARNINGS 3...

Страница 3: ...as well as disinfectant feed ratios AWARNING DO NOT increase pump size this will increase the flow rate through the system and exceed the maximum flow rate stated on the drain cover AWARNING Before in...

Страница 4: ...o avoid dangerous or fatal electrical shock turn OFF power to the pump before working on electrical connections NOTE Always turn off all power to the pool pump before installing the cover or working o...

Страница 5: ...system shall be constructed so that it shall not allow for separate or independent shutoff or isolation of each drain More than one pump can be connected to a single suction line as long as the requi...

Страница 6: ...erious or fatal electrical shock hazard DO NOT ground to a gas supply pipe line AWARNING The system s centrifugal pump operates with electrical voltage and can generate both vacuum and pressure in the...

Страница 7: ...ASE ALL PRESSURE from the pump and the piping system before proceeding NEVER tighten or loosen screws while the pump is operating Do not block pump suction AWARNING Do not block pump suction To do so...

Страница 8: ...water pressure resulting in damage to the pump casing impeller and mechanical seal Such damage will not be covered under warranty 6 GENERAL MAINTENANCE AWARNING To prevent damage to the pump and for p...

Страница 9: ...eal Low Pump Capacity Valve in suction or discharge line is partly closed Open or replace the valve Suction or discharge line is partly plugged Clear the obstruction Suction or discharge line is too s...

Страница 10: ...OVER RCAGP 080337F 2 3 3 KIT O RING FOR LID RCAGP 080338F 4 KIT BASKET WITH HANDLE RCAGP 080339F 5 KIT 1 5 NPT UNION KIT RCAGP 080340F 6 7 7 KIT 1 5 UNION O RING RCAGP 080341F 8 KIT PUMP BASE RCAGP 08...

Страница 11: ...tered with Raypak www raypak com warranty then the Applicable Warranty Period is one 1 year from the Effective Date for the PUMP and component parts LABOR AND SHIPPING COSTS This Limited Warranty does...

Страница 12: ...TO MAKE ANY OTHER WARRANTIES ON RAYPAK S BEHALF ANY IMPLIED WARRANTIES INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYOND THE APPLICABLE WARRANTY PERIOD SPECIFIED IN...

Страница 13: ...l entretien de ce type d quipement et de ses composantes connexes Dans certaines r gions les techniciens d entretien pour ce type d quipement doivent d tenir une licence Les personnes non qualifi es...

Страница 14: ...on D marrage Ajout de trois puces la section Amor age Remplacement de la figure 3 par une nouvelle illustration qui contient le s lecteur de vitesse article 11 Ajout de l article 11 au tableau C TABLE...

Страница 15: ...d ajout de produit d sinfectants AAVERTISSEMENT N augmentez PAS la capacit de la pompe cela augmentera le d bit travers le syst me et d passera le d bit maximal indiqu sur le couvercle du drain AAVERT...

Страница 16: ...ique dangereux ou mortel coupez l alimentation de la pompe avant de toucher les connexions lectriques NOTE coupez toujours l alimentation de la pompe de piscine avant d installer le couvercle d aspira...

Страница 17: ...x convergent dans une seule conduite d aspiration celle ci peut tre quip e d une vanne coupant l alimentation des deux drains la pompe Le syst me doit tre construit de fa on ce qu il ne soit pas possi...

Страница 18: ...en courant alternatif Le fait de ne pas mettre le moteur la terre peut entra ner un risque de choc lectrique grave ou mortel NE PAS mettre la terre un tuyau d alimentation en gaz r la masse entra ne...

Страница 19: ...ib rez tout l air du filtre et du syst me de tuyauterie voir les instructions relatives au filtre ci dessous Dans un syst me d aspiration inond source d eau sup rieure la pompe la pompe s amorce par e...

Страница 20: ...re pour serrer le couvercle Mettez sous tension le disjoncteur de la maison Facultatif R glez l horloge de la piscine l heure correcte D marrez la pompe en basculant son interrupteur d alimentation su...

Страница 21: ...uvrir ou remplacer la vanne La vanne dans la conduite d aspiration ou de d charge est partiellement bloqu e liminer l obstruction La conduite d aspiration ou de d charge est sous dimensionn e Refaire...

Страница 22: ...COVER RCAGP 080337F 2 3 3 KIT O RING FOR LID RCAGP 080338F 4 KIT BASKET WITH HANDLE RCAGP 080339F 5 KIT 1 5 NPT UNION KIT RCAGP 080340F 6 7 7 KIT 1 5 UNION O RING RCAGP 080341F 8 KIT PUMP BASE RCAGP 0...

Страница 23: ...rranty la p riode de garantie applicable est d un an compter de la date d entr e en vigueur pour la pompe et les composants CO TS DE MAIN D UVRE ET D EXP DITION Cette garantie limit e NE couvre PAS le...

Страница 24: ...E RAYPAK AUCUNE GARANTIE IMPLICITE NOTAMMENT DE QUALIT MARCHANDE OU D APTITUDE R PONDRE UN USAGE PARTICULIER NE SAURAIT TRE INTERPR T E DANS UN SENS QUI D PASSE LES P RIODES DE GARANTIE APPLICABLES NO...

Отзывы: