Parameter

Specification

Dimensions

(excluding rack ears)

3.49” H, 17.125” W, 12.5” D

2 RU

Weight

16.4 lb (7.5 kg)

Air Filter

Washable foam

Input Voltage

85 to 264 VAC

Power Consumption

65 W, maximum

Table A-1  

Communications Specifications

Port

Specification

Ethernet

10/100 BASE-T

RS-232 serial

Baud: 9600 to 15,200

Bits: 8

Stop bits: 1

Parity: None

Flow control: XOn/XOff

Содержание Linx DVI

Страница 1: ...Linx DVI 8x8 Matrix Switcher User s Guide Revision 1 1 May 2008 ...

Страница 2: ...o this guide or the information contained herein at any time without notice All features functions and specifications are subject to change without notice or obligation COMPANY ADDRESS RGB Spectrum 950 Marina Village Pkwy Alameda CA 94501 Telephone 510 814 7000 Fax 510 814 7026 ACKNOWLEDGEMENT The RGB Spectrum Web Control Panel WCP uses the GoAhead WebServer Copyright 2003 GoAhead Software Inc All...

Страница 3: ...ave no obligations under this warranty with respect to any defect unless it receives notice and a description of such defect no later than five 5 business days following the expiration of the warranty period THE WARRANTIES STATED HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE I...

Страница 4: ...o Inputs and Outputs 5 Control Connections 5 RS 232 Control 5 10 100 BASE T Control 6 Power 6 Chapter 2 Communications Setup 7 Serial Communication 7 Launching a HyperTerminal Window 7 Ethernet Control 9 Setting the PC IP Address 10 Beginning a Telnet Session 11 Changing the Linx DVI 8x8 Matrix Switcher IP Address 13 Chapter 3 Operation 14 Command Line Operation 14 System Settings 14 Communication...

Страница 5: ... Parameter Values 31 Query the Current Setting 31 Commands Summary 31 Communications Commands 34 Switch Commands 36 Preset Commands 38 EDID Commands 39 Miscellaneous Commands 42 Chapter 5 Transferring Files and Updating Firmware 44 Transferring Files 44 Downloading a File from the Linx Switcher 44 Uploading a File to the Linx Switcher 46 Update System Firmware 48 Chapter 6 Maintenance and Troubles...

Страница 6: ...350 8794 V1 1 Linx DVI 8x8 Matix Switcher User s Guide iii Appendix B Contact Information 56 ...

Страница 7: ...Figure 3 1 XY Control Panel 18 Figure 3 2 XY Control Panel Ready to Take Change 19 Figure 3 3 Presets Page 19 Figure 3 4 Matrix Status Page 20 Figure 3 5 System Information Page 21 Figure 3 6 Entering the IP Address in the Browser 22 Figure 3 7 Web Control Panel 23 Figure 3 8 Routing Window 23 Figure 3 9 Preview Preset Routings 24 Figure 3 10 Configuration Tab 25 Figure 3 11 Presets Tab 26 Figure ...

Страница 8: ...ds 36 Table 4 4 Preset Commands 38 Table 4 5 EDID Commands 39 Table 4 6 Miscellaneous Commands 42 Table 6 1 Troubleshooting Guide 50 Table A 1 Physical Specifications 51 Table A 1 Communications Specifications 51 Table A 2 Digital Input and Output Specifications 52 Table A 3 DVI Connector Pin Assignments 52 Table A 4 Ethernet Connector Pin Assignments 54 Table A 5 RS 232 Connector Pin Assignments ...

Страница 9: ...x 1080p at 60Hz EDID management Automatic pass through Programmable input or output Automatic or selectable cable equalization on inputs up to 50 meters Pixel reclocking on input and output Embedded operating system Temperature controlled fan with washable front panel filter Multiple control methods Front panel touch screen Command interface serial or network Graphic user interface over Ethernet S...

Страница 10: ...gure 1 1 Linx DVI 8x8 Matrix Switcher Front Panel All connections are made on the rear panel of the Linx Switcher Figure 1 2 Linx DVI 8x8 Matrix Switcher Rear Panel Features on the rear panel include active link power alarm L in x D V I 8 x 8 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 10 100 BASE T RS 232 ...

Страница 11: ...ters within the Linx Switcher Display EDID Contains EDID for each output passed through from the display device The contents of the display register may be saved as an entry in the EDID list Emulated EDID Contains EDID for each output selected from the EDID list Fixed EDID Contains fixed EDID for each input selected from the EDID list The factory default resolution for each register is 1280 x 1024...

Страница 12: ...ut EDID priority is applied to emulated and display pass through data Only active outputs are considered when establishing priority Active outputs are those having parameters stored in the Linx Switcher EDID display register these may be outputs currently connected or those with assigned emulated EDID EDID LIST The EDID list is used to apply parameters to the fixed and emulated EDID registers Entr...

Страница 13: ...the length in meters of the cable Each cable is unique relative to the amount of equalization it may require Tune equalization by entering higher or lower levels to reach the final setting The input equalization command INputEQualizer is described on page 36 input equalization is not available on the front panel or WCP INSTALLATION RACK MOUNTING If the Linx Switcher is to be rack mounted it should...

Страница 14: ... configuration the computer is provided with a suitable IP address by a network DHCP server When connecting directly to the Linx Switcher a server will not be available a static IP address must be set manually on the computer Refer to the Setting the PC IP Address on page 10 Note The Linx Switcher is configured at the factory with the default IP address 192 168 1 200 Before connecting to a network...

Страница 15: ...is provided in Chapter 4 on page 30 PCs running the Microsoft Windows operating system are provided with serial emulation software known as HyperTerminal This provides a convenient method to communicate with the Linx Switcher Use the following steps to launch a HyperTerminal window on a PC 1 Connect the Linx Switcher to a PC as described in section RS 232 Control on page 5 2 Click Start Programs A...

Страница 16: ...e of which is shown below Figure 2 2 Connection Description Dialog 3 In the dialog Enter a name Choose an icon Click OK to display the Connect To dialog box Figure 2 3 Connect To Dialog 4 In the Connect To dialog box ignore the Country Area Code and Phone Number fields In the Connect Using field select the PC s COM port to which the serial cable from Linx Switcher is connected ...

Страница 17: ...cher by typing ver and pressing ENTER The current firmware version should be displayed If not check the settings outlined above and repeat ETHERNET CONTROL The Linx DVI 8x8 Matrix Switcher can be controlled from the 10 100 Base T Ethernet port using either a graphical user interface or a command line interface The graphical interface uses a standard web browser such as the Microsoft Internet Explo...

Страница 18: ... Windows operating system use the procedure below to set the PC network address to one compatible with the Linx Switcher 1 Use an Ethernet crossover cable or hub to connect directly between the Linx Switcher s Ethernet port and the network port of a PC 2 From the PC Start menu select Control Panel 3 In the Control Panel select Network Connections 4 In Network Connections right click on Local Area ...

Страница 19: ...LNET SESSION With the IP address of the PC set a Telnet session can be started 1 From the PC Start menu at the bottom of the Windows desktop select Run 2 In the Open dialog box type cmd as shown in Figure 2 7 Figure 2 7 Run Window 3 Click OK to open the Windows command window 4 At the prompt in the command window type telnet ipaddress 8000 where ipaddress represents the Linx DVI 8x8 Matrix Switche...

Страница 20: ...2 168 1 200 8000 and press ENTER 5 At the Password prompt type RGB and press ENTER The password must be entered in upper case At this point the Telnet window starts and the Linx DVI 8x8 Matrix Switcher responds with the product name and copyright notice as shown in the figure below Figure 2 8 Telnet Connected To change the Linx Switcher IP address see the following section Note To close a Telnet s...

Страница 21: ...ept the new address or n to retain the current address If y is pressed in the step above the Linx Switcher reboots and the Telnet connection is lost 3 To re establish the Telnet connection press ENTER to display the command prompt Type telnet ipaddress 8000 using the new IP address In addition to setting the IP address the IP subnet mask IPSubNET and gateway IPGateWay can also be set as required T...

Страница 22: ...S 232 or Ethernet connection See Chapter 2 on page 7 for establishing communication with these ports Commands are grouped in the following categories System Settings Communication Settings Switch Settings Presets EDID Exporting and Importing System Settings SYSTEM SETTINGS The Linx Switcher can operate without making modification of any system settings However commands are provided to set paramete...

Страница 23: ...nput source to an output destination A single input can be routed to one or more output destinations OUTputENable Enables disables one or all outputs OUTputSouRCe Associate an output to an input An output can only be associated with a single input INputEQualizer Compensate for the losses caused by the electrical and physical characteristics of a DVI cable PRESETS Presets define specific input outp...

Страница 24: ...list entries EXportEDID Exports an EDID list entry to memory for FTP transfer IMportEDID Imports an EDID list entry after FTP transfer EXPORTING AND IMPORTING SYSTEM SETTINGS System settings can be exported to a text file and transferred to a PC for subsequent import back to a Linx Switcher It is recommended that settings be exported prior to updating firmware Exporting and importing can also be u...

Страница 25: ...ows advanced users to use third party software to make changes to timing parameters AL L In addition to the preset EDID and system parameters All includes the communication values for baud rate echo and handshake IMPORTSETTINGS After a settings file has been uploaded from a PC to the Linx Switcher this command is issued to load the saved values ...

Страница 26: ... on the bottom of the window To enable a new configuration on a page touch the TAKE button XY CONTROL PANEL The XY Control Panel can be used to view the current output input assignments or to make changes to those assignments See Figure 3 1 Use the up or down arrows to step through the outputs to view the current inputs assigned To change the input assigned to an output 1 Use the up or down arrow ...

Страница 27: ...ing preset routings Front panel operation does not support the creation or assignment of presets Stepping through the presets TAKE will be displayed in reverse contrast Figure 3 3 Presets Page XY CONTOL PANEL OUTPUT 03 Conference Room 04 Input number 4 INPUT XY PST STAT SYS TAKE Note If TAKE is not pressed before selecting a different page the selection made on the XY Control Panel will be lost PR...

Страница 28: ...nt assignment If there is no diamond in a row no change will be made to that output Use the Matrix display to determine current routing To select a preset routing 1 Use the up or down arrow to step to the desired preset 2 Touch TAKE to change to the displayed preset The TAKE button will change to normal video STATUS PAGE The status page displays the current routing of input to output ports If a va...

Страница 29: ... Update System Firmware on page 48 for information on updating firmware Hardware version No change possible FPGA version Displays the current FPGA version This is automatically updated when the firmware is updated IP Address Indicates the current IP address Change the setting using a command line interface or the web control panel WCP Baud Rate Displays the current baud rate of the RS 232 interfac...

Страница 30: ...Windows font size should be set to Normal 96 DPI for correct display of the WCP To verify this setting Select Display from the Windows Control Panel Click on the Settings tab Click on Advanced Select Normal 96 DPI Ensure a copy of Java Runtime Environment software version 1 4 2 1 5 0 or higher is installed on the PC The software version may be referred to 4 2 and 5 0 A copy of Java is provided on ...

Страница 31: ...about preset or current input output routing Routing changes can be made by clicking on the desired row column Any input may be routed to one or more outputs Figure 3 8 Routing Window Notice that as the cursor is moved over the routing window the input and output numbers are highlighted Select Preset Load Selected Pres Preview Preset ut Status ut Names Output Names Enable Disable Out Routing ...

Страница 32: ...ure 3 9 Preview Preset Routings Enable Disable Outputs Enabled outputs are indicated in green Click an output number to disable it diabled outputs are indicated in red Output Names Displays the names assigned using the Configuration tab to the eight outputs Input Status A detected valid input is indicated in green Red indicates no input Routing The current routing is indicated by green dots preset...

Страница 33: ...utput EDID or select a Fixed EDID from the drop down list EDID assignment corresponds to the EDIDMode command See EDID Control in Chapter 1 for more information Priority Rule When dynamic EDID is selected for an input routed to multiple outputs the priority rule determines which output EDID will be used The priority can be the output with the lowest resolution or the lowest numbered output Output ...

Страница 34: ...d viewed from this tab but cannot be loaded click another tab to enable preset loading Figure 3 11 Presets Tab Preset List Select a preset number 1 to 99 from the drop down list Show Preset s Routings Check to display the indicated preset in the routing window Delete Click to delete the indicated preset A window opens asking to confirm or cancel the deletion Create Preset Click Save to save the ro...

Страница 35: ...y be saved to the EDID list Displayed EDID information includes the name manufacturer s ID and manufacturer s model code Figure 3 13 EDID Tab EDID List Select an EDID entry from 1 to 100 Previously saved information will be displayed Save After an EDID list entry and an output port have been selected click Save to save the display information Rename Use to rename an existing EDID list entry Delete...

Страница 36: ...rts modifications to the network and serial port settings Product information and current system temperature are displayed Figure 3 14 System Tab N E T W O R K S E T T I N G S Network settings can be modified Enter new data and click Apply Hostname Enter an optional name for the Linx Switcher IP Address If the IP address is changed the WCP must be restarted by entering the new address in the brows...

Страница 37: ...al number is factory entered and not subject to change MAC Address The MAC address is factory entered and not subject to change Board Temperature Displays the current system temperature WCP Version Displays the version number of the WCP Version number updates when the WCP software is updated S E R I A L P OR T Baud Select a baud rate from the drop down list The default is 9600 Echo Turn echo on or...

Страница 38: ... short form version is an abbreviation of the command name indicated in bold face upper case However commands are not case sensitive The command BAUDrate could be entered in four different ways BAUDRATE baudrate BAUD baud COMMAND HELP S Command Help There are two primary ways to use the Linx Switcher s help feature Type Help to list all commands Type Help followed by the command to get command spe...

Страница 39: ...o establish the current parameters associated with the command enter the command without any arguments Linx Switcher will respond with the current settings of the selected parameter S Example To display the current IP address of the Linx Switcher enter the IPADDRess command without entering an argument Typing the command IPADDR might return 192 168 1 201 COMMANDS SUMMARY Note Do not use the delete...

Страница 40: ...tatus IPADDRess Communication Sets or reports the Linx Switcher IP address IPGateWay Communication Sets or reports the network gateway IP address IPSubNET Communication Sets or reports the subnet mask LiStEDID EDID Lists EDID information for one or more EDID list entries LiStPreSeT Switch Shows routing for a range of presets LoaDEmulateEDID EDID Loads EDID parameters to the specified emulate regis...

Страница 41: ...ll routing for selected preset number SYStemINFO Miscellaneous Reports model serial number IP and Ethernet addresses firmware version SYStemReSeT Miscellaneous Restarts the system without powering off and on SYStemTIME Miscellaneous Sets or reports system time UpdateFirmWare Miscellaneous Updates the system firmware VERsion Miscellaneous Reports the firmware version Table 4 1 Alphabetical List of ...

Страница 42: ... Turns the serial echo On Off Example To turn the echo off type echo off and press ENTER Omit the argument to display the current state Default ON HANDShaking HardWare SoftWare Sets the type of flow control on the serial port Hardware handshaking uses CTS RTS control Software handshaking protocol is XON XOFF Example To set handshaking to hardware type hands hw and press ENTER Omit the argument to ...

Страница 43: ...s to 192 168 1 102 type ipgw 192 168 1 102 and press ENTER Use the SYStemReSeT command to reboot the unit to activate the new IP gateway address Without an argument this command reports the current IP gateway address Default 192 168 1 1 IPSubNET ddd ddd ddd ddd Changes the IP subnet address of the Linx Switcher Example to set the IP subnet address to 255 255 255 1 type ipsnet 255 255 255 1 and pre...

Страница 44: ...al and the number of any associated outputs Example To display the status of input 1 type instat 1 and press ENTER NAMEINput input input name Enter an input number and the name to be assigned to it The name can be up to 23 alphanumeric characters spaces are permitted Example To assign the name Level 3 to input 3 type namein 3 Level 3 and press ENTER If a name is not entered the command will return...

Страница 45: ... status OUTputSouRCe output input Enter the output number followed by the number of the input to be assigned Example To route input 2 to output 7 type outsrc 7 2 and press ENTER To get the current status for the specified output omit the input argument ROUTE input output Enter the input number followed by the desired output assignment An input can be assigned to one or more outputs Example To rout...

Страница 46: ...ame For a preset name enter a maximum of 23 alphanumeric characters spaces may be used Example To name preset 11 Training type namepst 11 Training and press ENTER Without a preset name this command returns the current name of the preset number entered RECALLPreSeT preset Enter the desired preset number to load input output assignments Example To load preset 15 type recallpst 15 and press ENTER SaV...

Страница 47: ...fied with the LoaDEmulateEDID command PASSthrough provides EDID from the display connected to the specified output Example To set the display mode to PASSthrough for output 4 type displaymode 4 pass and press ENTER To display the current setting do not enter a mode EDIDPRiority input ALL MINRES OUTNUM In DYNAMIC mode with an input routed to multiple outputs this command sets minimum resolution or ...

Страница 48: ...EDID list output Saves the EDID parameters of the specified output to the EDID list number entered Example Save the EDID information of output 6 to timing index number 31 type svedid 31 6 and press ENTER DELeteEDID EDID list ALL Deletes the EDID information from the specified EDID list number Example To clear all EDID settings from the EDID list type deledid all and press ENTER NAMEEDID EDID list ...

Страница 49: ...apter 5 for instructions on downloading and uploading files Example To save EDID list entry 15 to file dell_2 txt type exdid 15 dell_2 txt and press ENTER If the filename is omitted it is automatically generated from the name of the EDID list entry IMportEDID EDID list file name txt Imports a single entry from the Linx Switcher memory to a specified EDID list index The file name is case sensitive ...

Страница 50: ...Settings on page 16 for details on stored parameters Example To export the routing of all presets to a file named Presets type exportsettings presets Presets txt and press ENTER Default file name export txt IMPORTSETTINGS file name txt Loads a list of system attributes from a saved file The file must include the extension txt See Exporting and Importing System Settings on page 16 for details on lo...

Страница 51: ...eturns the current system time Example To set the system time to 9 30 15 on June 20 2007 type 2007 06 20 09 30 15 and press ENTER UpdateFirmWare none Refer to Update System Firmware on page 48 for a complete discussion of updating firmware VERsion none Reports the system front panel and channel processors firmware versions Table 4 6 Miscellaneous Commands Continued Command Arguments Description ...

Страница 52: ...d with the EXportEDID or EXPORTSETTINGS command 1 From the PC Start menu at the bottom of the Windows desktop select Run 2 In the Run dialog box type cmd as shown in Figure 5 1 Figure 5 1 Run Window 3 Press ENTER or click OK to open the command window Figure 5 2 illustrates the following steps 4 Change to the desired PC directory In the figure below the directory linx is selected 5 At the prompt t...

Страница 53: ...ownload export txt a file created with the EXPORTSETTINGS command is listed in Figure 5 2 9 Type get file_name txt and press ENTER to copy the file to the PC In the example shown above the command is get export txt Note that the filename is case sensitive 10 Type bye and press ENTER to disconnect from the Linx Switcher 11 Type dir and press ENTER to view file copied to the PC 12 Close the command ...

Страница 54: ...Change to the PC directory containing the file to be uploaded In the figure below the directory linx is selected 5 Type dir and press ENTER to verify the desired file is present 6 At the prompt type ftp followed by the IP address and press ENTER In the example below the IP address is 192 168 1 220 7 When prompted for a user name enter rgb in lowercase and press ENTER 8 Enter the password spectrum ...

Страница 55: ...TR A N S F E R R I N G F I L E S A N D U PD A T I N G F I R M W A R E Transferring Files 350 8794 V1 1 Linx DVI 8x8 Matix Switcher User s Guide 47 Figure 5 4 FTP Upload Session ...

Страница 56: ...View the System tab of the WCP 2 Download the latest revision of the firmware from the RGB Spectrum web site Support section http www rgb com en Support The upgrade is a file named FWLNX_x y z tgz where x y z represents the version number The file name is case sensitive Copy this file onto a local drive on the PC The use of a broadband connection is highly recommended Do not rename the file 3 Foll...

Страница 57: ...t and dirt are a problem it is recommended that the filter be inspected weekly If the Linx Switcher overheats the alarm indicator on the front panel will light Overheating may be caused by 1 Operating in an environment with a temperature exceeding 122 F 50 C 2 Failed fan or blocked air intake 3 Clogged air filter wash or replace Wash the filter in mild dish detergent Rinse in clear water Press it ...

Страница 58: ...mple telnet 192 168 34 70 8000 Cannot connect to host Check that the PC has a static IP address compatible with the Linx Switcher and network Output No output present Output has been disabled Use OUTputENable to display or change an output status The display is not capable of the resolution sent to it Set the output display mode to pass through and the EDID mode of the input to dynamic When a sing...

Страница 59: ...ons Parameter Specification Dimensions excluding rack ears 3 49 H 17 125 W 12 5 D 2 RU Weight 16 4 lb 7 5 kg Air Filter Washable foam Input Voltage 85 to 264 VAC Power Consumption 65 W maximum Table A 1 Communications Specifications Port Specification Ethernet 10 100 BASE T RS 232 serial Baud 9600 to 15 200 Bits 8 Stop bits 1 Parity None Flow control XOn XOff ...

Страница 60: ...n digital input and output specifications Only the digital pins of the DVI I connector are used Figure A 1 DVI Input and Output Connectors Table A 2 Digital Input and Output Specifications Parameter Specification Type DVI single link Number 1 Maximum bandwidth 1 65 Gbps Standard resolution 640 x 480 to 1600 x 1200 HD resolution 920 x 1080p 1920 x 1200 and 2048 x 1080p Connector type DVI I Table A ...

Страница 61: ...de 53 7 DDC data 8 9 TMDS data 1 10 TMDS data 1 11 TMDS data 1 3 shield 12 13 14 5V power used at 300 mA 15 Ground 16 Hot plug detect 17 TMDS data 0 18 TMDS data 0 19 TMDS data 0 5 shield 20 21 22 TMDS clock shield 23 TMDS clock 24 TMDS clock Table A 3 DVI Connector Pin Assignments Continued Pin Signal ...

Страница 62: ...chitecture Internal Linx DVI 8x8 Matrix Switcher web server provides the Web Control Panel WCP a graphical user interface via a standard web browser Figure A 2 Ethernet Connector The 10 100 BASE T port can connect to a network using a standard Ethernet cable When a network is not used connection requires an Ethernet hub or a crossover cable Table A 4 Ethernet Connector Pin Assignments Pin Signal W...

Страница 63: ...s serial protocol at 9600 to 115 000 baud The port is configured as DCE and can handle full duplex transfer Support for hardware and software handshaking is provided Figure A 3 RS 232 Connector Table A 5 RS 232 Connector Pin Assignments Pin Circuit Description 1 CD Carrier Detect 2 TD Transmit Data 3 RD Received Data 4 not connected 5 AB Signal Ground common return 6 DSR Data Set Ready 7 CTS Clear...

Страница 64: ...N RGB Spectrum can be reached by phone fax mail and e mail as listed below RGB Spectrum 950 Marina Village Parkway Alameda CA 94501 Phone 510 814 7000 Fax 510 814 7026 E Mail technical support support rgb com E Mail sales and product information sales rgb com Website www rgb com ...

Отзывы: