C O M M A N D S
Switch Commands
350-8794 V1.1
Linx DVI 8x8 Matix Switcher User’s Guide
36
. . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S W I T C H C O M M A N D S
Table 4-3
Switch Commands
Command
Arguments
Description
IN
put
EQ
ualizer
<input # | ALL>
<OFF | AUTO | level>
Defines the equalization setting for one or all
inputs. See
Input Equalization
in
Chapter 1
.
Level values are 1 to 50.
Example
: To set the equalization level of input 3
to 25, type:
ineq 3 25
and press
ENTER
.
To display the current equalization value, enter
only the input argument.
IN
put
STAT
us
<input #>
The status display will include the input number,
yes or no to indicate the presence of a valid input
signal, and the number of any associated
outputs.
Example
: To display the status of input 1, type:
instat 1
and press
ENTER
.
NAMEIN
put
<input #> <input name>
Enter an input number and the name to be
assigned to it. The name can be up to 23
alphanumeric characters; spaces are permitted.
Example
: To assign the name “Level 3” to input
3, type:
namein 3 Level 3
and press
ENTER
.
If a name is not entered, the command will return
the current name of the indicated input.
NAMEOUT
put
<output #>
<output name>
Enter the desired output number followed by the
name to be assigned. The name can be up to 23
alphanumeric characters; spaces are permitted.
Example
: To assign the name “Conference
Room” to output 5, type:
nameout 5 Conference Room
and
press
ENTER
.
If a name is not entered, the command will return
the current name of the indicated output.