C O M M U N I C A T I O N S S E T U P
Ethernet Control
350-9047 v3.0.1
DGy Model 201x User’s Guide
136
. . . . .
IP ADDRESS SETUP
. . . . . . . . .
VIA ETHERNET
DGy 201x
’s IP address can be set directly via Ethernet, using a Telnet
session that enables remote login to the
DGy 201x
from a computer.
This procedure is not required if the IP address was set using the
method described in the
IP Address Setup via Serial Port
section on
page 135.
Use the following procedure to set up the IP address with a Telnet
session:
1.
Use an Ethernet crossover cable or Ethernet hub to connect
directly between the
DGy 201x
’s Ethernet port the network port
of the PC.
2.
From the Start menu at the bottom of the Windows desktop
select
Run
...
3.
In the
Open
dialog box type
cmd
as shown in the following
figure.
Figure B-5
Run Dialog Box
4.
Click the
OK
to open the Windows command window.
5.
At the command prompt in the command window type:
telnet <ipaddress> 8000
where <
ipaddress
> represents
DGy 201x
’s current IP address.
S
Example
: If the
DGy 201x
default IP address has not been
changed, it should be set to:
192.168.1.200
Using the default IP address shown above, in the command line
window, type:
telnet 192.168.1.200 8000
... and press
ENTER
.
Note
For this procedure, the
direct
connection method is
recommended over the network method. This avoids
potential conflicts between
DGy 201x
’s default IP
address and the network.