C O M M A N D L I N E I N T E R F A C E
Commands
350-9047 v3.0.1
DGy Model 201x User’s Guide
97
. . . . .
. . . . . . . . .
AUDIO COMMANDS
The table below lists all
DGy 201x
audio commands, their arguments
and detailed descriptions.
Table 6-4
Audio Commands
Command
Arguments
Description
AUD
io
FREQ
uency
<11.025 | 22.05 | 44.1>
Sets the sample rate in kHz of the audio input.
Default: 44.1 (CD quality).
AUD
io
M
o
D
e
<L | R | Stereo | OFF>
Determines which, if any, audio source is recorded.
If
AUDioMoDe
is set to
L
or
R
, the audio is routed
to both output channels on replay.
If
AUDioMoDe
is set to Stereo, the Left and Right
audio channels are routed independently to the Left
and Right audio output connectors (Stereo or
separate audio).
If
AUDioMoDe
is set to OFF, audio is not recorded.
Note
: This command does not affect playback. A
clip containing audio will be replayed independent
of the setting of this command.
Default: OFF
AUD
io
PHANT
om
<ON | OFF>
Supplies the low voltage phantom power, required
by some electronic microphones. The setting of
AUDioPHANTom
is ignored unless
AUDioSouRCe
is
MIC
.
Default: OFF
AUD
io
S
ou
RC
e
<MIC | LINE>
Determines whether input sensitivity is appropriate
for microphone or line level signals. If
AUDioSouRCe
is set to
LINE
, phantom power is
disabled automatically (but the setting of
AUDioPHANTom
remains unchanged).
Default: LINE