9.3 Records Parameters
9.3.1 Sorting (ID=1010)
Record sorting parameter is responsible for record sorting order. Value of 0
arranging data starting from the newest, while the value of 1 arranging data
starting from the oldest.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
U8
9.3.2 Active Data Link Timeout (ID=1011)
Defines for how many seconds device will keep a connection to the server after
successful data transfer while waiting for a new record.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
259200
-
U32
9.3.3 Server Response Timeout (ID=1012)
Defines time period (in seconds) for server response to sent
records.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
300
-
U8
ATTENTION!
Some GSM operators may disconnect the device
from an active data link if the device doesn’t send any data for a
very long time, even if active data link timeout is set to maximum
value. The amount of time that an operator keeps the link open