6.7.TROUBLESHOOTING
Before starting any intervention
Affix a sign indicating that maintenance is in progress.
1. Before starting the machine, always make sure that no one is carrying out cleaning or maintenance opera
tions.
2. Ask qualified and enabled electricians to check and perform small electrical repair operations.
3. Contact the authorised assistance service to repair mechanical parts.
Below is the list of interventions useful to resolve faults and to release the mobile elements, which can be carried out by mainte
-
nance technicians.
Type
Potential cause
Mode
No mains voltage
"General black out
Intervention of fuses or circuit
breakers upstream of the power
supply to the machine"
“Contact the electrical energy supplier.
Restore the protection device once you have solved the cause
that triggered it.
In the event the problem persists, contact an electrician.”
"Operation
interruption"
Intervention of the protection
device inside the machine
“Restore the protection device once you have solved the
cause that triggered it.
In the event the problem persists, contact an electrician.”
“The machine does not work
both the tank and tool fail to
rotate”
“No voltage
Disconnecting devices
“ OFF “
Fuses triggered or
Magneto-thermal switches do
not work
Failure
start button
Thermal trip
“
"Check and restore the power supply.
Turn the disconnecting devices to position
“ ON “
Replace the triggered fuses, check the state of the circuit
breakers.
Check the efficiency of the START button
Wait for the machine to cool down before restarting it"