13. Technical Data
Operating voltage..............................230 V/AC , 50 - 60 Hz
Connection output.............................3680 W (230 V/AC, 16 A)
Temperature switching points ........Max. 4
Programmes.......................................Weekdays Monday.....Friday
Weekend Saturday/Sunday
Temperature control range .............+5 °C to +45 °C
Temperature tolerance ....................±1 °C
Switching contact .............................Relay, single-pole
Ambient conditions ...........................Temperature -10 °C to +60 °C, humidity max. 90%
relative, non-condensing
Sensor cable length..........................Approx. 2 m
Dimensions.........................................80 x 80 x 50 mm
Weight .................................................171 g