6
Electrical requirements
Electrical requirements
The
SPA
2
is powered from the a.c. mains supply via an IEC 320 connector. The electrical ratings of the
unit are as follows:
100 – 240 V ac +10%, -15%
47 – 63 Hz
650 W maximum
This equipment must be connected to a protective earth conductor via a three core mains (line) cable. The
mains plug shall be inserted only into a socket outlet provided with a protective earth contact. The
protective earth contact shall not be negated by the use of an extension cable without protective
conductor.
An earth stud (M5 thread) is provided to allow bonding of the CMM metal parts to the protective earth.
WARNING:
Any interruption of the protective conductor may make the equipment dangerous.
Make sure that the grounding requirements are strictly observed.
Environmental requirements
The following environmental conditions comply with (or exceed) BS EN 61010-1:1993
Indoor use
IP20 (no protection against water)*
Altitude
up to 2000 m
Operating temperature
0 °C to +50 °C (local to
SPA
2
)
Storage temperature
-10 °C to +70 °C
Relative humidity
80% maximum (non-condensing) for
temperatures up to +31 °C.
Linear decrease to 50% at +40 °C
Transient overvoltages
Installation category II
Pollution degree
2
Weight
8 kg (17.6 lb)
NOTE:
If a higher IP rating is required an additional external enclosure will be required to house the
SPA
2
. This enclosure must facilitate an airflow to allow the internal temperature to maintain the ambient
within the
SPA
2
operating range.
!
Содержание apply innovation SPA2
Страница 1: ...Installation guide H 1000 5234 03 A SPA2 servo power amplifier...
Страница 3: ...SPA2 Installation guide...
Страница 15: ...System description 13 1 2 7 SPA2 and UCC2 system layout 1 2 8 SPA2 and UCClite...
Страница 34: ...32 Interconnection schemes 6 2 UCClite DC motor and tacho connection...
Страница 35: ...Interconnection schemes 33 6 3 Dual SPA2 DC motor and tacho configuration...