Hardware configuration of the SPA2
27
7. Included in the 4th axis interface card kit there are three 15 mm long PCB pillar mounts. These must
be attached to the three studs that are located to the left hand side of the enclosure and tightened to
ensure good earth continuity.
8. Position the 4th axis interface card into the location, as shown in diagram below.
9. Locate the 4
th
axis interface card onto the PCB pillar mounts using the M4 screws supplied with the
kit. Do not tighten these screws.
10. Using the pillars and washers supplied in the kit, locate the 4
th
axis interface connector through the
location hole in the rear panel of the
SPA
2
. Tighten these pillars and then tighten the screws inserted
in step 9.