Rev.2.00 Oct 16, 2006 page 38 of 354
REJ09B0340-0200
M30245 Group
2. Timer A
(1) To clear reset, the count start flag is set to “0”. Set a value in the timer Ai register, then set the
flag to “1”.
(2) The timer Ai interrupt request bit becomes “1” if setting operation mode of the timer in compli-
ance with any of the following procedures:
• Selecting PWM mode after reset.
• Changing operation mode from timer mode to PWM mode.
• Changing operation mode from event counter mode to PWM mode.
Therefore, to use timer Ai interrupt (interrupt request bit), set timer Ai interrupt request bit to
“0” after the above listed changes have been made.
(3) Setting the count start flag to “0” while PWM pulses are being output causes the counter to
stop counting. If the TAi
OUT
pin is outputting an “H” level in this instance, the output level
goes to “L”, and the timer Ai interrupt request bit goes to “1”. If the TAi
OUT
pin is outputting an
“L” level in this instance, the level does not change, and the timer Ai interrupt request is not
generated.
2.2.15 Precautions for Timer A (pulse width modulation mode)
Содержание M16C FAMILY
Страница 12: ...Chapter 1 Hardware...
Страница 13: ...See M30245 group datasheet...
Страница 14: ...Chapter 2 Peripheral Functions Usage...
Страница 303: ...THIS PAGE IS BLANK FOR REASONS OF LAYOUT...
Страница 304: ...Chapter 3 Examples of Peripheral Functions Applications...
Страница 340: ...Chapter 4 External Buses...
Страница 361: ...THIS PAGE IS BLANK FOR REASONS OF LAYOUT...
Страница 362: ...Chapter 5 Standard Characteristics...
Страница 369: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan M30245 Group REJ09B0340 0200 User s Manual...